Troubleshooting tables
Use the troubleshooting tables to find solutions to problems that have identifiable
symptoms.
If you have just added new software or a new optional device and the server is
not working, do the following before using the troubleshooting tables:
1.
Check the system-error LED on the operator information panel to see if it is lit.
2.
Remove the software or device that you just added.
3.
Run the diagnostic tests to determine whether the server is running correctly.
4.
Reinstall the new software or new device.
Hard disk drive boot error
A hard disk drive boot error can have the following causes.
Error
FRU/Action
The start-up drive is not in the boot
sequence in configuration.
Check the configuration and ensure the
start-up drive is in the boot sequence.
No operating system installed on the boot
drive.
Install an operating system on the boot
drive.
The boot sector on the start-up drive is
corrupted.
The drive must be formatted. Do the
following:
1.
Attempt to back up the data on the
failing hard disk drive.
2.
Using the operating system programs,
format the hard disk drive.
The drive is defective.
Replace the hard disk drive.
Power Supply Problems
If you suspect a power problem, use the following procedures.
Check/Verify
FRU/Action
Check the following for proper installation.
v
Power cord
v
On/Off switch connector
v
On/Off switch power supply connector
v
System board power supply connectors
v
Microprocessor(s) connection
Reseat connectors
Check the power cord for continuity.
Power cord
Check the power-on switch for continuity.
Power-on switch
16
ThinkServer TS200v Types 0981, 0992, 1008, and 1010: Hardware Maintenance Manual
Summary of Contents for ThinkServer TS200v
Page 1: ......
Page 2: ......
Page 3: ...ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Page 28: ...22 ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Page 34: ...28 ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Page 84: ...78 ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Page 107: ......
Page 108: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...