Note:
Do not remove the memory modules or microprocessors.
5. Remove the jumper cap from the jumper cap storage
4
.
6. Note the orientation of the jumper cap and then install the jumper cap on the clear password jumper.
7. Reinstall any parts and reconnect any cables. Then, reinstall the server cover. See “Completing the
parts replacement” on page 152.
8. Connect the server to an ac power source and wait for several minutes. Then, turn on the server. The
BIOS passwords are erased, including the administrator password and user password.
9. Repeat step 1 through step 3.
10. Move the jumper cap back to the jumper cap storage
4
.
11. Reinstall any parts and reconnect any cables. Then, reinstall the server cover. See “Completing the
parts replacement” on page 152.
12. Connect the server to an ac power source and turn on the server.
13. To set new passwords, see “Using passwords” on page 50.
2
BIOS default settings jumper
(Default setting: open)
Used to turn the BIOS settings into the factory default settings.
To turn the BIOS settings into the factory-default settings, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 61.
3. Remove the server cover. See “Removing the server cover” on page 61.
4. Locate the BIOS default settings jumper
2
on the system board. Then, remove any parts and
disconnect any cables that might impede your access to the jumper.
Note:
Do not remove the memory modules or microprocessors.
5. Remove the jumper cap from the jumper cap storage
4
.
6. Note the orientation of the jumper cap and then install the jumper cap on the BIOS default settings
jumper.
7. Reinstall any parts and reconnect any cables. Then, reinstall the server cover. See “Completing the
parts replacement” on page 152.
8. Connect the server to an ac power source and wait for several minutes. Then, turn on the server. The
BIOS settings turn into the factory-default settings.
9. Repeat step 1 through step 3.
10. Move the jumper cap back to the jumper cap storage
4
.
11. Reinstall any parts and reconnect any cables. Then, reinstall the server cover. See “Completing the
parts replacement” on page 152.
12. Connect the server to an ac power source and turn on the server.
3
BIOS recovery jumper
(Default setting: open)
Used to recover the BIOS if the power to your server is interrupted while the BIOS is being updated and your
server cannot start correctly.
To recover the BIOS, see “Recovering from a BIOS update failure” on page 53.
Chapter 3
.
Product overview
41
Summary of Contents for ThinkServer RD550
Page 14: ...xii ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 72: ...58 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 178: ...164 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 191: ......
Page 192: ......