![Lenovo ThinkServer RD550 User Manual And Hardware Maintenance Manual Download Page 139](http://html.mh-extra.com/html/lenovo/thinkserver-rd550/thinkserver-rd550_user-manual-and-hardware-maintenance-manual_202917139.webp)
5. Slide the new hot-swap hard disk drive into the drive bay from the front until it snaps into position
and then completely close the handle.
Figure 98. Installing the hot-swap hard disk drive
6. Check the hot-swap hard-disk-drive status LEDs to ensure that the hard disk drive is operating correctly.
You might have to restart the server for the newly installed hard disk drive to be recognized. See
“Hot-swap-drive status LEDs” on page 43. If the hard disk drive is faulty, you need to reinstall or
replace it until it is operating correctly.
7. Do one of the following:
• If you are installing a hot-swap hard disk drive, save the removed dummy hard-disk-drive tray in case
that you later remove the hot-swap hard disk drive and need a dummy tray to cover the drive bay.
• If you are replacing a hot-swap hard disk drive and are instructed to return the old hot-swap hard
disk drive, follow all packaging instructions and use any packaging materials that are supplied to
you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To configure RAID, go to “Configuring RAID” on page 54.
Installing or replacing an easy-swap drive
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 59.
This topic applies only to server models that have easy-swap drives installed. See “Features” on page 7 for
information about the supported easy-swap drives.
For a list of ThinkServer options, go to:
http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-server
The EMI integrity and cooling of the server are protected by having all drive bays covered or occupied. The
number of the installed drives in your server varies depending on the server model. The vacant bays are
either covered by an EMI-protective panel or occupied by dummy trays. When installing a drive, save the
removed dummy tray in case that you later remove the drive and need the dummy tray to cover the place.
Chapter 6
.
Replacing hardware
125
Summary of Contents for ThinkServer RD550
Page 14: ...xii ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 72: ...58 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 178: ...164 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 191: ......
Page 192: ......