• To complete the replacement, go to “Completing the parts replacement” on page 152.
Installing or replacing a hot-swap redundant power supply
Depending on the model, your server might come with one or two hot-swap redundant power supplies.
When the server is populated with two hot-swap redundant power supplies, the server can withstand a
power loss from either power supply. This helps you avoid significant interruption to the operation of the
server when a power supply fails. You can replace the failing hot-swap redundant power supply without
turning off the server.
Some server models come with only one power supply. You can purchase a hot-swap redundant power
supply from the Lenovo Web site at:
http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-server
CAUTION:
Hazardous moving parts. Keep fingers and other body parts away.
CAUTION:
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
Notes:
• To maintain the EMI integrity and cooling of the server, install a new power supply as soon as you remove
the failing one. Cover the other bay with a shield if you just use one power supply to provide power.
• Use any documentation that comes with the new power supply and follow those instructions in addition
to the instructions in this topic.
Installing a hot-swap redundant power supply
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 59.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
To install a hot-swap redundant power supply, do the following:
120
ThinkServer RD550 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer RD550
Page 14: ...xii ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 72: ...58 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 178: ...164 ThinkServer RD550 User Guide and Hardware Maintenance Manual ...
Page 191: ......
Page 192: ......