Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Redundancy Bckup Mem Status has
been reduced.
Error
Redundancy has been lost
and is insufficient to
continue operation.
1.
Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2.
Re-enable mirroring in the
Setup utility.
IMM Network Initialization
Complete.
Info
An IMM network has
completed initialization.
No action; information only.
Certificate Authority %1 has
detected a %2 Certificate Error.
(%1 = IBM_CertificateAuthority.
CADistinguishedName;
%2 = CIM_PublicKeyCertificate.
ElementName)
Error
A problem has occurred
with the SSL Server, SSL
Client, or SSL Trusted CA
certificate that has been
imported into the IMM. The
imported certificate must
contain a public key that
corresponds to the key pair
that was previously
generated by the
Generate a
New Key and Certificate
Signing Request
link.
1.
Make sure that the certificate
that you are importing is
correct.
2.
Try importing the certificate
again.
Ethernet Data Rate modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.Speed;
%2 = CIM_EthernetPort.Speed;
%3 = user ID)
Info
A user has modified the
Ethernet port data rate.
No action; information only.
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.FullDuplex;
%2 = CIM_EthernetPort.FullDuplex;
%3 = user ID)
Info
A user has modified the
Ethernet port duplex setting.
No action; information only.
Ethernet MTU setting modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.
ActiveMaximumTransmissionUnit;
%2 = CIM_EthernetPort.
ActiveMaximumTransmissionUnit;
%3 = user ID)
Info
A user has modified the
Ethernet port MTU setting.
No action; information only.
Ethernet Duplex setting modified
from %1 to %2 by user %3.
(%1 = CIM_EthernetPort.
NetworkAddresses;
%2 = CIM_EthernetPort.
NetworkAddresses;
%3 = user ID)
Info
A user has modified the
Ethernet port MAC address
setting.
No action; information only.
Ethernet interface %1 by user %2.
(%1 =
CIM_EthernetPort.EnabledState;
%2 = user ID)
Info
A user has enabled or
disabled the Ethernet
interface.
No action; information only.
Chapter 4. Diagnostics
43
Summary of Contents for ThinkServer 6531
Page 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Page 2: ......
Page 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 206: ...198 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 238: ...230 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 243: ......
Page 244: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...