Table 5. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service
technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
201-810-xxx
Memory
Memory Test
Aborted
Test stopped:
unknown error
code xxx
received in
COMMONEXIT
procedure.
1.
Turn off and restart the system.
2.
Run the test again.
3.
Make sure that the DSA code is at the latest level.
For the latest level of DSA code, go to
http://www.lenovo.com/support.
4.
Make sure that the server firmware is at the latest
level. The installed firmware level is shown in the
DSA event log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 212.
5.
Run the test again.
6.
If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..
201-901-xxx
Memory
Memory Test
Failed
Test failure:
single-bit error,
failing DIMM
z.
1.
Turn off the system and disconnect it from the
power source.
2.
Reseat DIMM z.
3.
Reconnect the system to power and turn on the
system.
4.
Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.lenovo.com/support.
5.
Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the DSA event log in the
Firmware/VPD section for this component. For
more information, see “Updating the firmware”
on page 212.
6.
Run the test again.
7.
Replace the failing DIMMs.
8.
Re-enable all memory in the Setup utility (see
“Using the Setup Utility” on page 200).
9.
Run the test again.
10.
Replace the failing DIMM.
11.
If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..
Chapter 4. Diagnostics
91
Summary of Contents for ThinkServer 6531
Page 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Page 2: ......
Page 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...