Attention:
To ensure proper cooling and airflow, do not operate the server for more than 30 minutes
with the cover removed.
4.
Remove the DIMM air baffle (see “Removing and installing the DIMM air baffle” on page 121).
5.
Carefully open the retaining clips
2
on each end of the DIMM connector and remove the DIMM
1
Attention:
To avoid breaking the retaining clips or damaging the DIMM connectors, open and close
the clips gently.
6.
If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing a memory module
v
The maximum operating speed of the server is determined by the slowest DIMM in the server.
v
If you install a pair of DIMMs in DIMM connectors 2 and 5, the size and speed of the DIMMs that you
install in DIMM connectors 2 and 5 must match each other. How ever, they do not have to be the same
size and speed as the DIMMs that are installed in DIMM connectors 1 and 4.
v
You can use compatible DIMMs from various manufacturers in the same pair.
v
When you install or remove DIMMs, the server configuration information changes. When you restart
the server, the system displays a message that indicates that the memory configuration has changed.
See “System-board internal connectors” on page 107 for the location of the DIMM connectors on the
system board.
To install a DIMM, complete the following steps:
1.
Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained
service technicians” on page 115.
2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables, if
necessary.
3.
Remove the cover (see “Removing and installing the cover” on page 119).
4.
Remove the DIMM air baffle (see “Removing and installing the DIMM air baffle” on page 121).
5.
Open the retaining clip
2
on each end of the DIMM connector.
Attention:
To avoid breaking the retaining clips or damaging the DIMM connectors, open and close
the clips gently.
Chapter 6. Replacing FRUs
125
Summary of Contents for ThinkServer 6531
Page 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Page 2: ......
Page 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 206: ...198 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 238: ...230 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Page 243: ......
Page 244: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...