5. Use other Lenovo tools to perform the update (ex. XClarity Administrator, XClarity Controller, or the
OneCLI utility).
6. If the error still occurs, contact service to support.
•
FQXPMUP0203M: BMC communication failed: EMMC2USB unmount failure. Failed to update the
firmware
Severity: Error
User Action:
1. Restart the BMC via BMC setting under uEFI setup on LXPM left panel.
2. Perform AC reset if the error still exist
Note:
When performing AC reset, after power off AC, wait several seconds before power on AC.
After AC power is restored, power on the host system.
3. Use other Lenovo tools to perform the update (ex. XClarity Administrator, XClarity Controller, or the
OneCLI utility).
4. If the error still occurs, contact service to support.
•
FQXPMUP0204M: BMC communication failed: Execute the update cmd failure. Failed to update the
firmware
Severity: Error
User Action:
1. Restart BMC via BMC setting under uEFI setup on LXPM left panel.
2. Perform AC reset if the error exist exist.
Note:
When performing AC reset, after power off AC, wait several seconds before power on AC.
After AC power is restored, power on the host system.
3. Use other Lenovo tools to perform the update (ex. XClarity Administrator, XClarity Controller, or the
OneCLI utility).
4. If the error still occurs, contact service to support.
•
FQXPMUP0205M: BMC communication failed: Get the update status failure.Failed to update the
firmware
Severity: Error
User Action:
1. Restart BMC via BMC setting under uEFI setup on LXPM left panel.
2. Perform AC reset if the error still exist.
Note:
When performing AC reset, after power off AC, wait several seconds before power on AC.
After AC power is restored, power on the host system.
3. Use other Lenovo tools to perform the update (ex. XClarity Administrator, XClarity Controller, or the
OneCLI utility).
4. If the error still occurs, contact service to support.
•
FQXPMUP0206M: The level of the update package is too old. Failed to update the firmware.
Severity: Error
User Action:
162
ThinkSystem SR250 Messages and Codes Reference
Summary of Contents for 7Y51
Page 1: ...ThinkSystem SR250 Messages and Codes Reference Machine Type 7Y51 7Y52 7Y72 and 7Y73 ...
Page 4: ...ii ThinkSystem SR250 Messages and Codes Reference ...
Page 8: ...4 ThinkSystem SR250 Messages and Codes Reference ...
Page 127: ...Information only no action is required Chapter 2 XClarity Controller events 123 ...
Page 128: ...124 ThinkSystem SR250 Messages and Codes Reference ...
Page 172: ...168 ThinkSystem SR250 Messages and Codes Reference ...
Page 174: ...170 ThinkSystem SR250 Messages and Codes Reference ...
Page 175: ......
Page 176: ...Part Number SP47A37842 Printed in China 1P P N SP47A37842 1PSP47A37842 ...