Figure 69. Fan cage assembly installation
Step 1. Align the fan cage assembly to the slots on both sides of the server, and lower it into the server.
Step 2. Rotate the fan cage release latches down until they click.
After installing the fan cage assembly, complete the following steps:
1. Install the chassis air baffle (see
“Install the chassis air baffle” on page 123
).
2. Install the top cover (see
“Install the top cover” on page 128
).
3. Reconnect the power cords and any cables that you removed.
4. If the server is installed in a rack, reinstall the server into the rack.
5. Power on the server and any peripheral devices.
Install the system board air baffle and the power interposer
Use this procedure to install the system board air baffle and the power interposer.
Before installing the system board air baffle:
1. Read the safety information and installation guidelines (see
).
2. Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
To install the system board air baffle, complete the following steps:
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/watch?v=pIb0bIyfkDY&=
PLYV5R7hVcs-Ak9fT8QAx8fLbEivizjRtp
Step 1. Slightly slide power supply 2 out from the power supply bay (see “Remove a hot-swap power
supply unit” in
ThinkSystem SR860 Maintenance Manual
).
110
ThinkSystem SR860 Setup Guide
Summary of Contents for 7X69
Page 1: ...ThinkSystem SR860 Setup Guide Machine Type 7X69 and 7X70 ...
Page 8: ...vi ThinkSystem SR860 Setup Guide ...
Page 62: ...54 ThinkSystem SR860 Setup Guide ...
Page 69: ...Chapter 3 Server hardware setup 61 ...
Page 82: ...74 ThinkSystem SR860 Setup Guide ...
Page 108: ...100 ThinkSystem SR860 Setup Guide ...
Page 162: ...154 ThinkSystem SR860 Setup Guide ...
Page 166: ...158 ThinkSystem SR860 Setup Guide ...
Page 171: ......
Page 172: ...Part Number SP47A30799 Printed in China 1P P N SP47A30799 1PSP47A30799 ...