Always install the drive backplane to the drive bay 0-7 when there is only one backplane.
• Two drive backplanes:
Two types of drive backplanes are supported by this system:
– 2.5-inch SATA/SAS 8-bay backplane (referred to as “8-bay backplane”)
– 2.5-inch AnyBay 8-bay backplane (referred to as “AnyBay backplane”)
When installing a AnyBay backplane and a 8-bay backplane, always install the AnyBay
backplane to drive bay 0-7, and the 8-bay backplane to drive bay 8-15.
Step 2. Align the tabs on the bottom of the drive backplane with the slots on the system board, and insert
them into the slots.
Step 3. Push the top of the drive backplane toward the front of the server until it clicks in place.
Figure 65. Drive backplane installation
Step 4. Apply drive bay labels based on the type of backplane installed. Several drive bay labels come with
each type of the supported drive backplane:
• 8-bay backplane
–
12-15 (NVMe)
Apply this label to drive bay 12-15 if an AnyBay backplane is installed to drive bay 8-15.
–
12-15
Apply this label to drive bay 12-15 if an 8-bay backplane is installed to drive bay 8-15
–
4-7
Apply this label to drive bay 4-7 if an 8-bay backplane is installed to drive bay 0-7.
106
ThinkSystem SR860 Setup Guide
Summary of Contents for 7X69
Page 1: ...ThinkSystem SR860 Setup Guide Machine Type 7X69 and 7X70 ...
Page 8: ...vi ThinkSystem SR860 Setup Guide ...
Page 62: ...54 ThinkSystem SR860 Setup Guide ...
Page 69: ...Chapter 3 Server hardware setup 61 ...
Page 82: ...74 ThinkSystem SR860 Setup Guide ...
Page 108: ...100 ThinkSystem SR860 Setup Guide ...
Page 162: ...154 ThinkSystem SR860 Setup Guide ...
Page 166: ...158 ThinkSystem SR860 Setup Guide ...
Page 171: ......
Page 172: ...Part Number SP47A30799 Printed in China 1P P N SP47A30799 1PSP47A30799 ...