Page 11
BLOWER DATA
G40UH−60D−135 with 1 hp motor PERFORMANCE − Bottom Return Air, Side Return Air with Optional RAB Return Air Base,
Return Air from Both Sides or Return Air from Bottom and One Side.
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
.00
0
2715
1280
1407
2255
1065
1070
1910
900
850
1660
785
674
.10
25
2640
1245
1403
2250
1060
1030
1900
895
834
1645
775
668
.20
50
2540
1200
1355
2245
1060
1006
1890
890
821
1630
770
665
.30
75
2480
1170
1319
2200
1040
975
1890
890
781
1625
765
656
.40
100
2390
1125
1282
2155
1015
940
1885
890
775
1615
760
642
.50
125
2320
1095
1251
2085
985
904
1860
875
758
1605
755
631
.60
150
2205
1040
1210
2020
955
876
1815
855
731
1595
750
611
.70
175
2080
980
1161
1935
915
839
1760
830
707
1545
730
588
.80
200
2010
950
1122
1855
875
810
1690
795
679
1495
705
568
.90
225
1880
885
1071
1755
830
781
1585
745
646
1430
675
545
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
G40UH−60D−135 with 1 hp motor PERFORMANCE − Single Side Return Air − Air volumes in bold require field fabricated
transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity.
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
.00
0
2455
1160
1336
2170
1025
1019
1850
875
829
1555
735
673
.10
25
2380
1125
1299
2140
1010
974
1840
870
812
1550
730
664
.20
50
2305
1085
1266
2105
995
947
1830
865
791
1545
730
656
.30
75
2235
1055
1234
2045
965
914
1820
860
774
1540
725
642
.40
100
2160
1020
1240
1985
935
886
1800
850
755
1540
725
628
.50
125
2065
975
1170
1925
910
863
1745
825
726
1535
725
614
.60
150
1990
940
1146
1870
880
844
1700
800
706
1505
710
599
.70
175
1895
895
1111
1775
835
808
1655
780
689
1465
690
573
.80
200
1805
850
1074
1680
790
779
1565
740
656
1425
670
562
.90
225
1695
800
1042
1590
750
752
1480
700
630
1335
630
533
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
G40UH−60D−155−1, −2, −3 with 3/4 hp motor PERFORMANCE − Bottom Return Air, Side Return Air with Optional RAB Re-
turn Air Base, Return Air from Both Sides or Return Air from Bottom and One Side.
External Static
Air Volume / Watts at Various Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
0.00
0
2380
1120
1135
2235
1055
1000
2060
970
875
1875
885
750
0.05
12
2340
1105
1130
2205
1040
990
2035
960
865
1840
870
745
0.10
25
2305
1090
1125
2180
1030
975
2015
950
855
1810
855
735
0.15
37
2265
1070
1105
2145
1010
960
1990
940
845
1790
845
725
0.20
50
2220
1045
1090
2105
995
945
1960
925
835
1765
835
720
0.25
62
2180
1030
1075
2080
980
935
1935
910
825
1740
820
710
0.30
75
2145
1010
1065
2050
965
925
1905
900
815
1715
810
700
0.40
100
2060
970
1040
1975
930
900
1845
870
795
1655
780
685
0.50
125
1955
925
1005
1890
890
870
1765
835
770
1610
760
670
0.60
150
1885
890
975
1795
850
840
1695
800
750
1560
735
655
0.70
175
1800
850
955
1730
815
815
1605
760
720
1480
700
635
0.80
200
1700
805
930
1630
770
785
1520
715
695
1405
660
615
0.90
225
1575
745
895
1525
720
760
1395
660
660
1285
605
585
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.