Page 12
BLOWER DATA
G40UH−60D−155−1, −2, −3 with 3/4 hp motor PERFORMANCE − Single Side Return Air − Air volumes in bold require field fab-
ricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x25 mm) cleanable air filter in order to maintain proper air
velocity.
External Static
Air Volume / Watts at Various Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
0.00
0
2230
1050
1080
2130
1005
945
1995
940
840
1830
865
745
0.05
12
2200
1035
1070
2105
990
935
1970
930
830
1810
855
735
0.10
25
2165
1025
1060
2075
980
930
1950
920
820
1795
845
725
0.15
37
2135
1005
1050
2040
965
915
1920
905
815
1765
835
720
0.20
50
2100
990
1035
2005
945
905
1890
895
805
1735
820
710
0.25
62
2050
965
1015
1975
930
895
1855
875
795
1705
805
700
0.30
75
2000
945
995
1940
915
880
1820
860
780
1675
790
690
0.40
100
1905
900
965
1860
875
850
1755
825
770
1630
770
680
0.50
125
1825
860
945
1780
840
830
1700
800
750
1555
735
660
0.60
150
1745
825
920
1690
795
805
1595
750
715
1495
705
645
0.70
175
1650
780
905
1610
760
785
1515
715
705
1430
675
625
0.80
200
1565
740
880
1520
715
755
1445
680
680
1330
630
605
0.90
225
1445
685
845
1385
655
720
1300
610
640
1225
580
575
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
G40UH−60D−155 with 1 hp motor PERFORMANCE − Bottom Return Air, Side Return Air with Optional RAB Return Air Base,
Return Air from Both Sides or Return Air from Bottom and One Side.
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
.00
0
2670
1260
1386
2325
1095
1048
1970
930
857
1700
800
706
.10
25
2580
1215
1342
2320
1095
1045
1965
925
842
1690
795
696
.20
50
2510
1185
1311
2255
1065
985
1960
925
817
1640
775
662
.30
75
2425
1145
1277
2210
1040
953
1955
920
803
1635
770
649
.40
100
2345
1105
1246
2150
1015
922
1925
910
778
1630
770
633
.50
125
2255
1065
1217
2095
990
897
1890
890
752
1615
760
618
.60
150
2170
1025
1182
2010
950
863
1840
870
733
1590
750
605
.70
175
2090
985
1139
1925
910
833
1785
840
708
1550
730
588
.80
200
1895
895
1106
1840
870
806
1710
805
683
1500
705
571
.90
225
1855
875
1064
1740
820
776
1620
765
655
1430
675
551
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
G40UH−60D−155 with 1 hp motor PERFORMANCE − Single Side Return Air − Air volumes in bold require field fabricated
transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity.
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
.00
0
2410
1135
1282
2175
1025
987
1870
880
833
1620
765
675
.10
25
2335
1100
1257
2140
1010
956
1860
875
810
1610
760
667
.20
50
2255
1065
1225
2085
985
918
1855
875
788
1605
755
658
.30
75
2205
1040
1200
2025
955
896
1830
865
764
1600
755
647
.40
100
2120
1000
1164
1975
930
874
1795
845
742
1595
750
628
.50
125
2040
960
1131
1905
900
847
1745
825
731
1575
745
618
.60
150
1955
920
1103
1835
865
820
1695
800
698
1540
725
601
.70
175
1870
880
1069
1760
830
792
1635
770
673
1465
690
568
.80
200
1770
835
1041
1670
790
763
1560
735
646
1415
665
548
.90
225
1660
785
1006
1585
745
740
1480
700
629
1345
635
527
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.