Page 9
BLOWER DATA
G40UH−60C−110 with 1 hp motor PERFORMANCE − Bottom Return Air, Side Return Air with Optional RAB Return Air
Base, Return Air from Both Sides or Return Air from Bottom and One Side.
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
.00
0
2655
1250
1407
2370
1120
1063
2085
985
894
1665
785
679
.10
25
2580
1215
1376
2350
1110
1043
2065
975
875
1650
780
667
.20
50
2500
1180
1346
2305
1085
1012
2045
965
849
1645
775
662
.30
75
2410
1135
1305
2230
1050
978
2010
950
820
1640
775
649
.40
100
2320
1095
1270
2165
1020
947
1940
915
786
1625
765
634
.50
125
2225
1050
1235
2090
985
914
1895
895
763
1610
760
622
.60
150
2130
1005
1205
2000
945
880
1840
870
740
1570
740
603
.70
175
2030
955
1155
1915
905
851
1760
830
709
1535
725
590
.80
200
1925
910
1123
1820
860
823
1670
790
681
1475
695
566
.90
225
1795
845
1078
1690
795
788
1560
735
655
1395
660
537
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
G40UH−60C−110 with 1 hp motor PERFORMANCE − Single Side Return Air − Air volumes in bold require field fabricated
transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity.
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium−High
Medium−Low
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
.00
0
2430
1145
1309
2245
1060
1006
1910
900
843
1635
770
686
.10
25
2355
1110
1277
2190
1035
978
1905
900
817
1620
765
677
.20
50
2280
1075
1242
2140
1010
950
1885
890
797
1610
760
667
.30
75
2205
1040
1218
2075
980
924
1860
875
782
1605
755
655
.40
100
2130
1005
1189
2005
945
905
1815
855
752
1595
750
636
.50
125
2045
965
1159
1920
905
864
1750
825
726
1565
740
619
.60
150
1955
920
1132
1850
875
840
1700
800
705
1525
720
605
.70
175
1860
875
1105
1760
830
817
1610
760
674
1475
700
582
.80
200
1755
830
1067
1670
790
789
1540
725
654
1395
660
560
.90
225
1645
775
1033
1575
745
763
1445
680
627
1325
625
540
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.