Position and safety sensors
149
Abbre-
viation
Function Description
S1
Pressure sensor
The pressure sensor detects the pressure in the im-
plement.
The pressure
is displayed on the operating terminal as the
spraying pressure.
is displayed as the EltecBase circulation system
pressure when the nozzles are switched off (SEH
boom).
is the determining value for various control func-
tions of the operating terminal.
S10
Flow meter
The flow meter detects the volume flow to the boom
in l/min.
S14
Tank content
The sensor detects the fill level of the main tank.
The fill level is displayed
with the display on the operating and setting cen-
tre.
on the operating terminal.
S3
Swing lock closed Detects the closed swing lock and enables vertical
folding of the arms 1 (-5).
S11
Swing lock open
Detects the opened swing lock.
S2
SEH Boom
Detects the angle of the slope compensation.
The positions of the slope compensation can be
displayed and controlled with the operating terminal.
S4 Height
adjustment:
Detects the various positions of the boom height.