Operation
98
16.2.1.10 Manual reduction of outer segments
If nozzles are sealed, e.g. with plugs, the outer left and right segments must be
reduced manually according to the sealed nozzles. The outer segments on the left
and right can be reduced in 50 cm steps by up to 1.50 m.
Press this key to access the display for
manual reduction of the outer segments.
The display for the manual reduction of the
outer segments appears.
L = left outer segment
R = right outer segment
To select the left or right side:
Press the rotary encoder to select the
value.
The corresponding number flashes
Turn the rotary encoder to enter the val-
ue.
Press the rotary encoder to save the
value.
WARNING
This setting is retained, even if the operating terminal is switched
off.
If a segment has been reduced, this dis-
play appears as information when the main
switch is activated.