Faults
146
18.7 Alarms
18.7.1 Segment box
Code Description
Possible
cause
Remedies
F1
Defective initiali-
sation process
Defective log-in to the op-
erating terminal
Switch off the operating
terminal and then switch it
on again
Check the connections
F2
Defective com-
munication
Segment box connected
before the operating termi-
nal was switched off
Switch off the operating
terminal and then switch it
on again
18.7.2 TankPilot electronic fill level monitoring
Code Description
Possible
cause
Remedies
NO-ID
Defective initiali-
sation process
Defective log-in to the op-
erating terminal
Switch off the operating
terminal and then switch it
on again
Check the connections
NO-
LIN
Defective com-
munication
The operating terminal is
switched off
Defective connections
Electronic fill level display
function not active
Switch on the operating
terminal
Check the connections
Have the setting checked
by your dealer
18.7.3 Joystick box
Code Description
Possible
cause
Remedies
F1
Defective initiali-
sation process
Defective log-in to the op-
erating terminal
Switch off the operating
terminal and then switch it
on again
Check the connections
F2
Defective com-
munication
Segment box connected
before the operating termi-
nal was switched off
Switch off the operating
terminal and then switch it
on again
F3
EcoControl func-
tion not activated
in the operating
terminal although
the joysick box is
connected.
Function not activated
Have the setting checked
by your dealer