Commissioning
32
11.3
Calibration of flow meter
A calibration of the flow meter must be carried out before the start of each season.
To determine the weight of the combina-
tion of the tractor and the implement,
fill the tank of the implement with water
to the nominal fill level.
Drive with the implement onto a level,
unsurfaced area, where the water can
easily soak away.
Switch on the PTO.
Carry out spraying until water emerges
from all nozzles.
Weigh the combination of the tractor and
the implement.
From the settings menu
press this key to access the implement
weight menu.
The display for entering the weight of the
combination of tractor and implement ap-
pears.
Press the rotary encoder to select the
value.
Turn the rotary encoder to enter the val-
ue.
Press the rotary encoder to save the
value.
Press this key to confirm the value.
Does the 'Pump switched on' display ap-
pear?