SVIK user and installation manual
19
mounted on PCB.
14. Strip 12mm of insulation for each of the 3-wires of the power supply
cable.
15. Insert the power supply cable through the bottom cable gland. To
maintain the protection class (IP54) of the charger, the supplied
cable gland must be used.
16. Open the levers of the WAGO™ connectors that are mounted on the
left side of the PCB.
17. Insert the 3-wires of the power supply cable into the WAGO™
connectors mounted on PCB and close each lever of the connectors.
Be sure that the wires are fully inserted into the connectors, no
stripped parts of the wires or strand wires must be visible (electrical
protection against direct contact). Incorrect connection can result in
improper contact which may cause a fire hazard.
CAUTION
Always follow the wires succession as labelled on
the PCB (printed circuit board). An improper wire
succession may lead to an electric shock which can
be fatal or cause serious physical injuries or fire.
18. Tighten the sealing nut of the cable gland, making sure that the
Fig. 7 Stripping insulation length for each of the 3-wires of
the power supply cable
Fig. 8 Wires succession of the power supply cable