FlexLine, 30
Operation
3
Operation
3.1
Instrument Setup
Description
This topic describes an instrument setup over a marked ground point using the laser
plummet. It is always possible to set up the instrument without the need for a
marked ground point.
Important features
•
It is always recommended to shield the instrument from direct sunlight and avoid
uneven temperatures around the instrument.
•
The laser plummet described in this topic is built into the vertical axis of the
instrument. It projects a red spot onto the ground, making it appreciably easier
to center the instrument.
•
The laser plummet cannot be used in conjunction with a tribrach equipped with
an optical plummet.
Tripod
When setting up the tripod pay attention
to ensuring a horizontal position of the
tripod plate. Slight corrections of inclina-
tion can be made with the foot screws of
the tribrach. Larger corrections must be
done with the tripod legs.
TSOX_012b