Page 48 of 61
7.2.3 Adjusting the distance between ink jet and ink drop voltage detector
JET Rapid Wire - JET Rapid Wire PI – JET Rapid option Speed Plus
After a reassembling of the drop production unit, it may be necessary to adjust the distance between
the ink drop voltage detector and the ink jet.
Attention
The following steps are only necessary after the entire drop production unit was disassembled
and reassembled e.g. after exchanging defective parts.
Do not carry out these steps for a standard ink jet adjustment!
Remove the head cover: Use the hex key to untighten the mounting screws of the cover. You do not
have to remove the screws.
The optimal distance between ink jet (illustrated as
blue dotted line
) and the surface of the ink drop
voltage detector is the half of the height
H (2mm)
of the
charging tunnel = 1 mm
Use the
set screw
to adjust the distance:
•
turn the screw to the
right
to increase the distance
•
turn the screw to the
left
to decrease the distance.
Set screw:
0
,
9 mm hex
Ink drop voltage detector
Ink jet
0,9mm
hex key /
Art Nr. 55-008669K
left
right
H