Page 24 of 61
3.6.2 Ink list JET Rapid Wire
INK
JET Rapid Wire
Stepped head cover
JET Rapid Wire
Beveled head cover
50
μ
m
50
μ
m
70-106
*)
70-126
70-134
72-102
76-101
*) Limitations regarding the cleaning intervals
All inks are approved for a ink temperature range between 20°C and 45°C. The temperature delta
during operation must not /- 7° C based on the ink temperature at the time of the last
calculation of the drop-break-off point whereby the ink temperature should never fall below 20°C and
never exceed 45°C.
3.6.3 Ink list JET Rapid Wire PI
INK
JET Rapid Wire PI
Stepped head cover
JET Rapid Wire PI
Beveled head cover
60
μ
m
60
μ
m
70-120
*)
*)
74-111
76-121
79-106
79-119
79-122
*) Limitations regarding the cleaning intervals
All inks are approved for a ink temperature range between 20°C and 45°C. The temperature delta
during operation must not /- 7° C based on the ink temperature at the time of the last
calculation of the drop-break-off point whereby the ink temperature should never fall below 20°C and
never exceed 45°C.
3.7 Cleaning requirements
Due to their compositions, some inks have limitations with regards to their cleaning intervals.
Especially inks that contain soot particles also require a more intensive cleaning. With such inks,
rinsing the electrode block and the deflection plates with cleaning fluid may not be sufficient. With such
inks, we recommended cleaning the deflection plates with a soft tissue in order to remove all stains
and particles.
Attention
Due to the higher printing speed of the JET Rapid printers, the number of printouts per
time unit may be much higher than with the JET3up.
Therefore, it is necessary to check the gutter tube for ink staining on a regular basis.
When required the gutter tube has to be cleaned from any ink stains.
Please see the manual and service documentation for the respective cleaning
instructions.