24
Control Panel
A control panel may be connected to the splitter
board by using the dry contact Up, Down and
Common connections. The control panel must
provide a momentary, dry contact closure of at least
1/2 second.
1. Use 3-conductor 20-24 gauge wire to connect the
control panel to the splitter board.
2. A momentary closure across the common and up
wires will be an “up” command.
3. A momentary closure across the common and down
wires will be a “down” command.
4. A momentary closure across the common, up and
down wires will be a “stop” command.
Operation & Limit Adjustment Wall Switch
1. Press “DOWN” button on screen switch and screen
will deploy out of case in downward direction.
2. Press “STOP” button on screen switch and screen
will stop if in movement.
3. Press “UP” button on screen switch and screen
will retract upward into case.
“Up”
Button
“Stop”
Button
“Down”
Button
“Up”
Button
“Down”
Button
European Style Wall Switch (220V models only)
1. Press “DOWN” button on screen switch and screen
will deploy out of case in downward direction.
2. Press “UP” button on screen switch and screen
will retract upward into case.
Up (Dry Contact)
Down (Dry Contact)
Common (Both)
Bus (Bus)
5V (Bus)
OPERATION OF SCREEN
THIRD PARTY CONTROL
Summary of Contents for DA-LITE Tensioned Advantage Series
Page 1: ...Tensioned Advantage Series USER MANUAL 200076 Rev C ...
Page 3: ...Tensioned Advantage with Closure Door USER MANUAL 200072 Rev C 88585 ...
Page 13: ...Tensioned Advantage USER MANUAL 200069 Rev C 84215 ...
Page 27: ...Tensioned Advantage with SightLine USER MANUAL 210747 Rev A DL15520 ...
Page 41: ...Tensioned Advantage Over 14 W with Closure Door USER MANUAL 200073 Rev C 35898 ...
Page 51: ...Tensioned Advantage Over 16 W USER MANUAL 200074 Rev C 35890 ...