23
If your Tensioned Advantage was ordered as a complete unit, the up and down limits were pre-set by Da-Lite. If your screen
and roller assembly was ordered separately from the case, or if general adjustment is needed, please follow the steps below
and refer to the Wiring Diagram.
1. Locate the wall switch and remove the cover plate from
the wall switch and remove the switch from the junction
box.
2. Locate the two tactile buttons on the back of the switch.
They are black round buttons on silver plates.
3. To adjust the down limit switch, press and hold the
down tactile button until the LED on the back of the
switch turns solid red. This will put the motor in limit set
mode. Turn the wall switch over and use the down
button on the front of the switch. Press and hold the
down button until the desired down position is reached.
If you travel too far down, press the up button to move
the screen upward. If you press and let go of either the
up or down buttons, the motor will do a small jog in that
direction for fine adjustment of the screen. Once the
desired position is reached, turn the switch over; press
and hold the down tactile button until the LED on back
of switch blinks red twice. The down limit is now set.
CAUTION: Do not adjust for more drop than what
was ordered. At least 1–1/2 wraps of fabric must
remain on
the roller.
ATTENTION! N'effectuez pas de réglage pour obtenir
un déroulement supérieur à celui commandé. Au
moins 1 à 1/2 tour de toile doit être maintenu sur le
cylindre.
NOTE: If the screen is in limit set mode and no buttons
are pushed for 20 seconds, the LED on the back of the
wall switch will turn off, the motor will return to run
mode and no changes will be saved. If this occurs,
return to step 3 for down limit adjustment or step 4 for
up limit adjustment.
NOTE:
All screens except Parallax standard with 12"
black drop at the top. Screens with Parallax surface
standard with 2" of black drop at the top.
4. To adjust the up limit switch, press and hold the up
tactile button until the LED on the back of the switch
turns solid green. This will put the motor in limit set
mode. Turn the wall switch over and use the up button
on the front of the switch. Press and hold the up button
until the desired up position is reached. If you travel too
far up, press the down button to move the screen
downward. If you press and let go of either the up or
down buttons, the motor will do a small jog in that
direction for fine adjustment of the screen. Once the
desired position is reached, turn the switch over; press
and hold the up tactile button until the LED on back of
switch blinks green twice. The up limit is now set.
CAUTION: Adjusting the down limit switch for less
drop by more than 6" can cause the screen surface
to lose proper tensioning.
ATTENTION! LE FAIT D'AJOUTER NE DÉROULEZ PAS
TROP L'ÉCRAN PLUS DE 15 CM (6PO) AUX
INTERRUPTEURS DE FIN DE COURSE PEUT FAIRE
PERDRE LA BONNE TENSION À LA SURFACE DE
L'ÉCRAN.
5. To test the limit switch settings, press and release the
up or down buttons on the switch to operate the screen.
6. Replace the switch and cover plate on the wall.
IMPORTANT NOTE: The wall switch is REQUIRED to
make any limit switch adjustments, even if a third party
control system is used. Therefore, it is advised to wire
the switch or provide a 3-conductor connection that is
accessible.
For Screens with Standard Built-In Low Voltage Control or Optional VPI
SCREEN ADJUSTMENT
UP
STOP
DOWN
BUS
C
O
M
5
V
Front of Wall
Switch
UP
STOP
DOWN
BUS
C
O
M
5V
LED
Up Limit
Tactile Button
Down Limit
Tactile Button
Back of
Wall Switch
Summary of Contents for DA-LITE Tensioned Advantage Series
Page 1: ...Tensioned Advantage Series USER MANUAL 200076 Rev C ...
Page 3: ...Tensioned Advantage with Closure Door USER MANUAL 200072 Rev C 88585 ...
Page 13: ...Tensioned Advantage USER MANUAL 200069 Rev C 84215 ...
Page 27: ...Tensioned Advantage with SightLine USER MANUAL 210747 Rev A DL15520 ...
Page 41: ...Tensioned Advantage Over 14 W with Closure Door USER MANUAL 200073 Rev C 35898 ...
Page 51: ...Tensioned Advantage Over 16 W USER MANUAL 200074 Rev C 35890 ...