10. Maintentance
10.2.2 The STATUS LED
The
STATUS
LED indicates the health of the device and sync status.
Ø
LED Static
If the LED is lit and static, then either the device is booting or there is an internal problem:
Static LED
System Status
Off
System powered off
White
System starting
Color (not white)
System failure
Ø
LED Blinking
If the LED is blinking at regular intervals, then the device is working properly and the LED indicates the sync
status.
Note that if the LED is blinking from white to a color, then this indicates that Power Core is running as a PTP
Master. The table below describes the possible states:
Blinking LED
Sync Status
Blue <-> Off
Synchronized to PTP master
Yellow <-> Off
Trying to sync to PTP master
Red <-> Off
Synchronized to internal clock
Green <-> Off
Synchronized via Wordclock
Magenta <-> Off
Synchronized via MADI
Red <-> white
Device is PTP Master, sync source = internal
Green <-> white
Device is PTP Master, sync source = Wordclock
Magenta <-> white
Device is PTP Master, sync source = MADI
10.2.3 Replacing Defective Parts
All rear panel IO cards are hot-pluggable which means that they can be exchanged during uptime. This allows
fast replacement of a card in the case of a hardware failure. Providing the card is of the same type and fitted to
the same rear panel slot as the faulty card, the new card will immediately take over the same functions.
Other components can be serviced by removing the top cover of the Power Core frame. You must disconnect
the unit from its power source to perform these operations.
Do
NOT
remove the cover while the device is powered.
For more information on these procedures, please contact your local Lawo representative or email