![Launch KWA-300 User Manual Download Page 30](http://html1.mh-extra.com/html/launch/kwa-300/kwa-300_user-manual_3871246030.webp)
LAUNCH KWA-300 3D Wheel Aligner Operation Instructions
4-15
Fig.4.51
Operating procedures:
[Log column]: To shown the abnormal conditions of the
equipment usage in each year.
[Save]: When there are records in the log file of system,
the required records can be saved by
clicking
button, and viewed by technical personnel,
checking the running conditions of equipment.
[Print]: The system has provided the printing function
which is convenient to view.
Note:
Besides the client information needs backup
operation regularly, we recommend that the log
records need back-up operation regularly, too, so as
to be convenient to repair and maintain the
equipment.
Target Monitoring
Target monitoring needs to be performed before test,
click the icon of [Target Monitor], the screen will display
the interface as shown in Fig.4.52.
Fig.4.52
Camera Calibration
Click the [Camera Calibration] icon, the system will enter
the interface as shown in Fig.4.53.
Fig.4.53
Enter the password, and click [OK] button, the interface
is as shown in Fig.4.54.
Fig.4.54
Click [Start Calibrating] icon, the interface is as shown in
Fig.4.55.
Fig.4.55
Turn the target according the prompts on the interface.
When the target is turned to some angle value, the
arrow head on the interface prompts to reset the target
in reverse direction. The interface is as shown in
Fig.4.56.