![Larson Davis Spartan 730 Reference Manual Download Page 39](http://html1.mh-extra.com/html/larson-davis/spartan-730/spartan-730_reference-manual_3719581039.webp)
Spartan 730/730IS Dosimeter Manual
Defining Exceedance Triggers
37
3.2.1 Setting Exceedance Trigger Levels On the Dosimeter
Step 1.
Press and hold
select
to open the dosimeter Menu.
Step 2.
Highlight, then
select
Settings
to enter the Settings menu.
Step 3.
Press
down
until
Trigger Levels
is highlighted, then press
select
. This
opens the Trigger Levels menu.
Step 4.
Press
down
to highlight the Trigger Level you want to set (SPL1, SPL2,
Peak1, Peak2, Peak3), then press
select
.
Adjusting a Trigger Level On the Dosimeter
•
Use
up
or
down
to change the digit.
•
Press
select
to set the digit and progress to the right.
•
Set all 4 digits to return to the menu.
•
Quick press
POWER
to step back to the left at any time.
Step 5.
Repeat step 4 to set additional Trigger Levels, then press and hold
power
to exit all menus.
3.2.2 Customizing Exceedance Trigger Settings
Use the processes in this section to edit how exceedance triggers are calculated.
IN THIS SECTION:
•
Setting the Frequency Weighting
•
Setting the Peak Frequency Weighting
•
In this section, use
UP
or
DOWN
on the dosimeter to
highlight an option. Use
SELECT
to set the option. Quick
press
power