show green-ethernet
Description
:
Show Green Ethernet (Power reduction).
Syntax
:
show
green-ethernet [ interface ( <port_type> [ <port_list> ] ) ]
show
green-ethernet eee [ interface ( <port_type> [ <port_list> ] ) ]
show
green-ethernet energy-detect [ interface ( <port_type> [ <port_list> ] ) ]
Parameters
:
|
Output modifiers
eee
Shows green Ethernet EEE status for a specific port or ports.
energy-detect
Shows green Ethernet energy-detect status for a specific port or ports.
interface
Shows green Ethernet status for a specific port or ports. port or ports.
short-reach
Shows green Ethernet short-reach status for a specific port or ports.
*
All switches or All ports
GigabitEthernet
1 Gigabit Ethernet Port
|
Output modifiers
<port_type_list> Port list for all port types
<cr>
Example
:
SISPM1040-582-LRT#
show green-ethernet eee
Interface Lnk EEE Capable EEE Enabled LP EEE Capable EEE In Power Save
---------------------- --- ----------- ----------- --------------- -----------------
GigabitEthernet 1/1 Yes Yes Yes No No
GigabitEthernet 1/2 No Yes Yes No No
GigabitEthernet 1/3 No Yes Yes No No
GigabitEthernet 1/4 Yes Yes Yes Yes Yes
GigabitEthernet 1/5 No Yes No No No
GigabitEthernet 1/6 No Yes No No No
GigabitEthernet 1/7 Yes Yes No Yes No
GigabitEthernet 1/8 No Yes No No No
GigabitEthernet 1/9 No No N/A N/A N/A
-- more --, next page: Space, continue: g, quit: ^C
SISPM1040-582-LRT#
show green-ethernet short-reach interface GigabitEthernet 1/3
Interface Lnk Short-Reach
---------------------- --- ------------
GigabitEthernet 1/3 No No
SISPM1040-582-LRT#