3: Installation
SLB™ Branch Office Manager User Guide
37
Note:
One possible use for the two Ethernet ports is to have one port on a private,
secure network, and the other on an unsecured network. Ethernet bonding is also
supported.
Connecting Terminals
The console port is for local access to the SLB unit and the attached devices. You may attach a
dumb terminal or a computer with terminal emulation to the console port. The SLB console port
uses RS-232C protocol and supports VT100 emulation. The default baud rate is 9600.
To connect the console port to a terminal or computer with terminal emulation, Lantronix offers
optional adapters that provide a connection between an RJ45 jack and a DB9 or DB25 connector.
The console port is configured as DTE. For more information, see the appendix,
www.lantronix.com/support
and click
Cable/Adapter
Lookup
on the Support menu.
To connect a terminal:
1. Attach the Lantronix adapter to your terminal (use PN 200.2066A adapter) or your PC's serial
port (use PN 200.2070A adapter).
2. Connect the Cat 5 cable to the adapter, and connect the other end to the SLB console port.
3. Turn on the terminal or start your computer's communication program (e.g., HyperTerminal for
Windows XP or lower. For recent versions of Windows use a free terminal emulator such as
PuTTY or TeraTerm Pro).
4. Once the SLB branch office manager is running, press
Enter
to establish connection. You
should see the model name and a login prompt on your terminal. You are connected.
Connecting to the Internal Modem
1. Connect an RJ11 telecommunication cable to the modem port on the front of the unit.
2. Connect the other end of the cable to an analog phone connector on your telephone network.
Caution:
To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG)
UL Listed or CSA Certified Telecommunication Line Cord.
Power
The SLB unit consumes less than 30W of electrical power.
Note:
Switched currents may be 30W or greater.
AC Input
The SLB branch office manager has a universal auto-switching dual AC inlet power supply. The
power supply for the 100-120 VAC SLB controller accepts AC input voltage between 100 and 120
VAC with a frequency of 50 or 60 Hz. The power supply for the 200-240 VAC SLB controller
accepts AC input voltage between 200 and 240 VAC with a frequency of 50 or 60 Hz. Rear-
mounted IEC-type AC power connectors are provided for universal AC power input on a single hot
line. US style two hot line 200-240VAC power is not supported. (See
.)
Caution:
This unit may have more than one power supply source. Disconnect all
power supply sources before servicing to avoid electric shock.