8: Device Ports
SLB™ Branch Office Manager User Guide
142
command. This action requires that a SLB user running the
runcli
command belong to a
group that is the same or greater than the group assigned to the script (e.g., if the script is
assigned to the Power group, the user running the
runcli
command must belong to the Power
or Admin group). For Batch Scripts, if this minimum group requirement is met, the SLB user
will temporarily be granted all of the individual rights assigned to the script while the Batch
Script is running. It is recommended that scripts that spawn clisession only be used with the
set script runcli
command (and not the
connect script
command), and that scripts
that spawn portsession only be used with the
connect script
command (and not the
set
script runcli
command).
Note:
Custom Scripts have a
debug enable
option that supports printing Expect
debug information to aid in creating an Expect script.The debug option is not
supported for Tcl and Python scripts.
Batch Script Syntax
The syntax for Batch Scripts is exactly the same as the commands that can be typed at the CLI,
with the additions described in this section.
The
sleep
command suspends execution of the script (puts it to 'sleep') for the specified number
of seconds. Syntax:
sleep <value>
The
while
command allows a loop containing CLI commands to be executed. Syntax:
while {<Boolean expression>} {
CLI command 1
CLI command 2
...
CLI command n
}
Note:
The closing left brace '
}
' must be on a line without any other characters. To
support a
while
command, the set command, variables, and secondary commands are
also supported.
Interface Script Syntax
This section describes the abbreviated scripting syntax for Interface Scripts. This limited syntax
was created to prevent the creation of scripts containing potentially harmful commands. Script
commands are divided into three groups: Primary, Secondary and Control Flow. Primary
commands provide the basic functionality of a script and are generally the first element on a line of
a script, as in:
send_user "Password:"
Secondary commands provide support for the primary commands and are generally not useful by
themselves. For example, the
expr
command can be used to generate a value for a set
command.
set <my_var> [expr 1 + 1]
Control Flow
commands allow conditional execution of other commands based on the results
of the evaluation of a Boolean expression.
Summary of Contents for 100-120 VAC SLB
Page 114: ...8 Device Ports SLB Branch Office Manager User Guide 114 Figure 8 4 Device Ports Settings ...
Page 131: ...8 Device Ports SLB Branch Office Manager User Guide 131 Figure 8 10 Devices Power Outlets ...
Page 174: ...9 USB Port SLB Branch Office Manager User Guide 174 Figure 9 3 Devices USB Modem ...