![Landis+Gyr E230 User Manual Download Page 76](http://html1.mh-extra.com/html/landis-gyr/e230/e230_user-manual_673713076.webp)
76/84
Error handling
© Gyr
D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual
Display
Description
If error is persistent
If error is transitional
Related
event
log #
00040000 Date
Time
invalid (TOU
meters only).
Billing based on energy
registers after the error
occurrence is not reliable
and may be subject to
discrepancies and
incorrect time-based
tariff switching. Billing
Profile (stored values)
will not be created
following this event type
and therefore Load
Profile data may also be
compromised. Maximum
Demand functions
independently of this
error type and is not
affected. Battery
Operating Time
functionality will no
longer be reliable once
this error bit is set.
Clear Error Register
F.F.0 on display and
readout by “Reset Error
Register” (W2 C150)
command using
.MAP110 or wait for the
error to be cleared
automatically after RTC
correction.
66
00020000 Error
accessing
EEPROM.
Meter operation may be
compromised. Billing
based on energy
registers after the error
occurrence is not
reliable.
Clear Error Register
F.F.0 on display and
readout by “Reset Error
Register” (W2 C150)
command using
.MAP110 or by power-
cycle.
N/A
00010000
UNUSED
00008000 Failed
checksum when
restoring
registers from
EEPROM. (No
backup of
registers
available.)
Meter operation may be
compromised. Billing
based on energy
registers after the error
occurrence is not
reliable. Error will only
occur during the power-
up sequence.
Clear Error Register
F.F.0 on display and
readout by “Reset Error
Register” (W2 C150)
command using
.MAP110 or by power-
cycle.
N/A