![Landis+Gyr E230 User Manual Download Page 14](http://html1.mh-extra.com/html/landis-gyr/e230/e230_user-manual_673713014.webp)
14/84
Introduction
© Gyr
D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual
2.4.5 Frequency
values
Rated Supply Frequency
50 Hz ±5%, 60 Hz ±5%
2.4.6 Power
consumption
In Voltage Path (ZxR1x0xR only)
U
n
110 V
U
n
230 V
Active at U
n
(typ.)
1.0 W (per
phase)
1.1 W (per
phase)
Apparent at U
n
(typ.)
1.0 VA (per
phase)
1.1 VA (per
phase)
In Voltage Path (ZxR1x0xC only)
U
n
110 V
U
n
230 V
Active at U
n
(typ.)
0.6 W (per
phase)
0.8 W (per
phase)
Apparent at U
n
(typ.)
0.6 VA (per
phase)
0.8 VA (per
phase)
In Current Path (ZxR1x0xC and ZxR1x0xR)
Apparent at 5A (typ.)
0.015 VA (per phase)
2.4.7 Temperature
values
Operating Temperature Range
-40°C to +70°C
Power Measurement Range
-40°C to +70°C
Storage Temperature Range
-40°C to +70°C
LCD Operating Temperature
From -25°C; will recover from
temperatures below
2.4.8 External
influences
Electromagnetic Compatibility
Electrostatic Discharges
IEC 61000-4-2
Contact Discharge – Conductive
Surfaces
8 kV
Air Gap Discharge – Non-Conductive
Surfaces
15 kV
Electromagnetic High Frequency
Fields
IEC 61000-4-3
80 MHz to 2 GHz
10 V/m & 30 V/m
Dwell Time
2 s
Line Transients (burst)
IEC 61000-4-4
Current and Voltage Circuits
4 kV
Auxiliary Circuits > 40V
2 kV
Rise Time
5 ns