63
Endurance Diagnostic Flow Chart:
ERROR CODE
DESCRIPTION
DIAGNOSIS
SOLUTION
ER01
Communication
Failure
Loss of communication from
the upper board to the
inverter board.
Check Upper Harness for
loose wires or connection.
1). Replace Upper Harness
2). Replace Display Board.
3). Replace Inverter Board.
ER02
Incline Motor
Error
Loss of elevation calibration
from the elevation motor to
the upper display board.
No elevation during use.
Check for loose wires or
connection. Run Auto
Calibration mode.
1). Replace Elevation Motor.
2). Replace Upper Harness.
3). Replace Upper Console.
4). Replace Inverter Board.
ER03
Safety Key Error
Loss of the safety key signal
from the remote control
console to the upper console
.
Check to see if the safety
key engaged properly into
the remote control
console.
1). Replace Remote Console.
2). Replace Ribbon Cable.
3). Replace Upper Console.
ER04
Over Current
Error
Upon start up the AC motor
runs faster than the inverter
board programmed speed.
Check wiring connection.
Perform an amp draw on
the belt and deck to see if
they are worn.
1). Replace Inverter Board.
2). Replace AC Drive Motor.
3). Replace Treadbelt & Deck.
ER05
AC Motor
Voltage Failure
When the Inverter board
monitors the AC motor is
either not getting enough or
too much voltage.
The inverter board or the
AC drive motor has
malfunctioned.
1). Replace Inverter Board.
2). Replace AC Drive Motor.
3). Replace Treadbelt & Deck.
ER06
AC Motor
Overload Error
This error code indicates that
the AC Motor’s Thermal
Sensor fails.
This error code occurs
when there is a high
friction on the belt
causing the Thermal
Sensor to pop on the
inverter board.
1). Replace Inverter Board.
2). Replace AC Drive Motor.
3). Replace Treadbelt & Deck.
Summary of Contents for L10
Page 1: ...1 L 10 Treadmill Service Manual Endurance and 9 Display Consoles ...
Page 3: ...3 Endurance Diagnostic Flow Chart 63 ...
Page 5: ...5 Service Claim Form ...
Page 14: ...14 Electrical Schematic ...
Page 15: ...15 Upper Consoles PST 7 CT 7 9 DISPLAY ENDURANCE DISPLAY ...
Page 57: ...57 Heart Rate Diagnostics Flow Chart ...
Page 58: ...58 No Power to Upper Console Endurance ...
Page 59: ...59 Safety Key Error Endurance Console ...
Page 60: ...60 No Power to the Upper Console 9 Series ...
Page 61: ...61 PO Error 9 Series ...
Page 62: ...62 Safety Key Error 9 Series ...
Page 64: ...64 L10 Bed Exploded View ...