background image

 

10.2  EXPLODED VIEW (CONTINUED)

Item  Part No. 

Description

  1   02-0040  

Seal,Extrusion

  2   02-0114  

Grommet,Compressor

  3   03-0150  

Retainer,Clip,Convert

  4   04-0034  

Nut,Lck,1/4-20 X 7/17 X  

 

13/16 Wshr

  5   04-0059  

Scr,8-36 X .375, PHD, LNB,  

 PH/Sl

  6   04-0072  

Rivet, .125 Od X .312 Lg, SS

  7   04-0297  

Nut, Hex, 8-32, Keps, SS

  8   04-0357  

Scr,10-32 X .375, 

 

 PHD,PH,MS,SS

  9   04-0406  

Scr,8-32 X .375 PH, PH, MS,  

 

SS, PL

  10   04-0407  

Scr,6-32 X .375, PHD, PH,  

 

Type 23, SS

  11   04-0504  

Scr,8-18X.375,PHD W/   

 

ELW, PH, AB

  12   04-0537  

Washer,.467Id X .923 OD  

 

X .060 Thk

  13   04-1206  

Scr,1/4-20X3/8,Bnh,Hs,Ss

  14   04-1453  

Screw,3/8-16X1-1/2,    

 PHD,PH,MS,ZP

  15   04-1537  

Scr,1/4-20X.500,HH,H/W,  

 

MS, SS, P

  16   04-1574  

Scr,8-32X1.250, PH, PH/ SL,  

 

RL, SS

  17   04-1645  

Nut,8-32,TH,NY

  18   04-1646  

Standoff, 8-32X.375, M-F,  

 

.750 Long, SS

  19   05-1502  

Plug, Key Hole

  20   05-2596  

Spacer,Pl,.50Idx1.50odx.625

  21   05-3030  

Bumpon,Tall Taper  

 

 Sq,.81X.30,Black

  22   05-3043  

Cover,Temp Probe,Liv

  23   05-3048  

Cover,Electronics

  24   05-3130  

Deck,Air Prop,Liv

  25   05-3141 

Bracket,Rack,Left,Liv

  26   05-3142  

Bracket,Rack,Right,Liv

  27   06-0075-01  

Nmplt,Vinyl,Pn/Sn/Elec Only

  28   06-3316  

Label,Wiring Diagram,Liv

  29   06-3366  

Label,Inside Door,Livingstone

  30   07-0211  

Washer,Shipping Base

  31   08-0184  

Tubing, Gry Drain 5/8Id X  

 7/8Od

  32   11-0008  

Tie,Wire

  33   11-0648  

Clamp, Cable, .250/.172,  

 

Black, Nylon

  34   12-0524  

Relay, Power, 30A, 240Vac

  35   12-0562  

Terminal Block, Rohs, 1/4”,  

 

6-12 Position

  36   13-0008  

Bushing,Relief,Heyco 1200

  37   15-0223  

Grommet,Flex,Slot .085W  

 X.155D

  38   18-0332  

Reg,Assy,Liv

  39   23-1554  

Rack,Liv

  40   23-1611  

Dryer/Cap Tube Assy,    

 .031X72”

Item  Part No. 

Description

  41   30-11146  

Condenser,Ducting,Liv

  42   30-11153  

Cover,Evap,Liv

  43   30-11154  

Panel,Front,Liv

  44   30-11156  

Cup Rest,Liv

  45   30-11158  

Hinge,Top,Mount,Liv

  46   30-11159  

Hinge,Bottom,Mount,Liv

  47   30-11230  

Frame,Support,Liv

  48   30-11240  

Fan Motor Cover,Cabinet,Liv

  49   30-11284  

Panel,Rear Access,Liv 

  50   30-11286  

Regulator,Shield,Air  

 

 Propulsion,Liv

  51   30-11442  

Shelf, Bottom, Livingstone

  52   30-11463  

Rack,3.8L Keg, Backstop,  

 Livingstone

  53   30-11516  

Frame,Base-Tray,Liv

  54   42-0175  

Foamed,Assy,Liner,Liv

  55   47-0344  

Tube,Process

  56   47-2238  

Tube,Process,Comp,600

  57   47-5699  

Evaporator Coil,Liv

  58   47-5724  

Suction Tube,Comp,Liv

  59   47-5725  

Tube,One,Comp,Liv

  60   47-5726  

Tube,Two,Comp,Liv

  61   47-5731  

Tube,Suction,Liv Deck

  62   50-0211  

Boot,6”,Delta Ii

  63  50-0322  

Baffle,Condenser,Side,600

  64   50-0640  

Foam,Insert,Stage,Liv

  65   51-0061  

Accumulator,.375Holes

  66   51-6427  

Shroud,Assy,Fan,Liv

  67   52-1258  

Fan Mtr Assy, 115V, 9W, 500,  

 R134a

  68   52-3002  

Thermostat,Digital,W/Probe

  69   52-3368  

Lead Assy,18Awg,12”,Blk,W/ 

 

Wht Strip

  70   52-3369  

Harness,Recirc Fan Ext,  

 Livingstone

  71   52-3370  

Harness,Main,Livingstone

  72   52-3371  

Harness,Thermostat    

 Controller,Livingstone

  73   52-3372  

Lead Assy, 18Awg, Blk,   

 Stranded

  74   81-0684  

Filter,Air,Liv

  75   82-4424  

Door,Assy,Liv

  76   82-4432  

Liv,Stage,Assy

  77   82-4469  

Liv,Air Propulsion Assy,115V

  78   82-4473  

Fan,Air Recirc,115/60

  79   83-0058  

Comp Assy,115-60Hz

  80   N/A  

1 Tower

27

Summary of Contents for UTC

Page 1: ...729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com JUNE 2013 FOR QUALIFIED INSTALLER ONLY UNDER THE COUNTER BEER DISPENSER Operation Manual Lancer is the registere...

Page 2: ...8 1 1 UNPACKING 8 9 1 2 SELECTING A LOCATION 9 1 3 ASSEMBLING THE UNIT 9 1 4 CONNECTING TO ELECTRICAL POWER 10 1 5 CONNECTING THE DRAIN 10 1 6 EQUIPMENT SETUP 10 2 GETTING STARTED 10 2 1 SETTING AND A...

Page 3: ...FROST CYCLE SEEMS TO BE TOO LONG FOR THE 115V MACHINE 22 6 13 CONDENSER FAN DOES NOT SHUT OFF 22 6 14 PRESSURE REGULATOR IS MALFUNCTIONING 22 6 15 UNIT IS IN STANDBY MODE 22 7 PROGRAMMING THE COOLING...

Page 4: ...IONS Width 23 6 inches 599 4 mm Depth 25 7 inches 652 8 mm Height 57 13 inches 1451 5 mm Tower Height 17 25 inches 438 2 mm SPACE REQUIRED Left Side 1 inch 25 4 mm Right side 1 inch 25 4 mm Back 1 inc...

Page 5: ...2 Tap handles 2 Casters 2 with brakes 2 without brakes 5 PRE INSTALLATION CHECKLIST BEFORE GETTING STARTED Each unit is tested under operating conditions and is thoroughly inspected before shipment At...

Page 6: ...ma para el dispensador es de 40 F a 86 F 4 4 C a 30 C No coloque la unidad de lado incluso durante el transporte No deje la puerta del armario abierta m s tiempo del necesario mientras el dispensador...

Page 7: ...saci n correcta de la cerveza No manipule el control del regulador de presi n No utilice ninguna otra fuente de presi n externa No conecte el barril proporcionado a cualquier otra fuente de presi n ex...

Page 8: ...tiene un enchufe puesto a tierra de 3 clavijas Si no se dispone de un toma el ctrico conectado a tierra de tres agujeros use un m todo aprobado para poner a tierra la unidad Al hacer las conexiones r...

Page 9: ...due to non use for a long period e G A holiday always remove the connected keg from the dispenser and dispose of it Once a keg has been connected the beer stays fresh for 30 days Siempre lea y siga l...

Page 10: ...cording to the surgeon general women should not drink alcoholic beverages during pregnancy because of the risk of birth defects Consumption of alcoholic beverages impairs your ability to drive a car o...

Page 11: ...properly grounded electrical outlet and to a drain or bucket that meets the requirements on pages 4 and 5 C The selected location must allow the unit to be leveled on all sides D The dispenser may be...

Page 12: ...ENCHUFE A UN TOMACORRIENTE A MENOS QUE EL VOLTAJE DE LA PLACA DE N MERO DE SERIE QUE SE MUESTRA ACEPTE LA CORRIENTE LOCAL MANTENGA EL DISPENSADOR CONECTADO EN TODO MOMENTO A MENOS QUE LAS INSTRUCCION...

Page 13: ...MENT IL EST RECOMMAND DE R GLER LA PRESSION L INT RIEUR DE LA PLAGE ADMISSIBLE POUR OBTENIR UNE DISTRIBUTION DE BI RE AD QUATE NE PAS JOUER AVEC LE CONTR LE DE R GULATION DE PRESSION A The pressure re...

Page 14: ...ONES DE VENTILACI N Y LAS ESQUINAS AVERTISSEMENT UNE MANIPULATION PRUDENTE EST REQUISE LORS DU D PLACEMENT DE L UNIT DE L ENTRETIEN ET L UTILISATION MANIPULEZ TOUJOURS L UNIT AVEC SOIN POUR VITER TOUT...

Page 15: ...some beer leakage and spillage in and around the dispenser A Place the keg vertically in front of the unit B Close the air valve C Open the release valve air will be released D Release for at least 30...

Page 16: ...he beer B THE SACRIFICE Your bartender opens the tap in one swift motion to let the first burst of foam flow away It must never enter the chalice glass thus ensuring that every drop of Stella Artois i...

Page 17: ...and 3 sanitary gloves WARNING IF A POWDER SANITIZER IS USED DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO ADDING TO THE SYRUP SYSTEM ENSURE SANITIZING SOLUTION IS REMOVED FROM THE DISPENSER AS INSTR...

Page 18: ...minimum of five gallons of sanitizing solu tion should be prepared Any sanitizing solution may be used as long as it is prepared in accor dance with the manufacturer s written recommendations and saf...

Page 19: ...SHOOTING GUIDE FOR END USER G J H K I 17 TROUBLE CAUSE REMEDY 5 1 Too much foam when beer dispensed A Beer is not cold enough B Tap not fully open C Pouring ritual not executed correctly D Glass not c...

Page 20: ...must be loaded on the top shelf of the refrigerator Make sure the kegs are inserted properly and pushed completely to the back Refer to Section 2 2 Connecting the Kegs B The keg connector must be fir...

Page 21: ...nnector Check if the valve on the beer tubing is in the open position Make sure that the beer tubing is untangled and check for any obstruction If issue still persists please replace the keg C Check t...

Page 22: ...nance and Cleaning to manually relieve the accumulated water from the tank If still not enough air flow then replace air compressor or inspect the air regulator B Replace air regulator 6 3 Air compres...

Page 23: ...ace main relay 6 7 Excessive ice build up around evaporator area A 115V machine has a defrost function which may need adjustment B 230V machine does not have a defrost function A Defrost can be modifi...

Page 24: ...re rated to withstand high pressure however this will result in a highly accelerated beer dispense from tap when opened A Close the beer valve and check the correct setting of the pressure regulator I...

Page 25: ...on until PA1 displays on the screen B When PA1 displays press the SET button once 0 will now display C When 0 displays press the UP button once setting the value to 1 When 1 displays press the SET but...

Page 26: ...ADJUSTING THE REFRIGERATION COMPRESSOR RELAY TRIPPING DIFFERENTIAL A Press the SET button until CP displays on the screen B When CP displays press SET once diF will display 1 diF is the refrigeration...

Page 27: ...10 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 10 1 WIRING DIAGRAM 25...

Page 28: ...10 2 EXPLODED VIEW 26...

Page 29: ...6 13 0008 Bushing Relief Heyco 1200 37 15 0223 Grommet Flex Slot 085W X 155D 38 18 0332 Reg Assy Liv 39 23 1554 Rack Liv 40 23 1611 Dryer Cap Tube Assy 031X72 Item Part No Description 41 30 11146 Cond...

Page 30: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: