2.4   CONNECTING A NEW KEG

 

 

To connect a new cooled keg, refer to Section 2.2 Connecting the Kegs.

 

2.5   KEG USE AND STORAGE CAUTION

 

 

A.  Store a connected keg using the racks in the dispenser.

 

 

B.  Make sure the dispenser is switched on at all times, unless stated otherwise in the instructions.

 

 

C.  If dispenser is switched off due to non use for a long period (e.g. holiday), always remove the

 

 

 

connected keg from the dispenser and dispose of it.

 

 

D.  Once a keg has been connected, the beer stays fresh for 30 days.

 

 

E.  Make sure the air lines and beer tubing are free and not entangled nor pinched.

 

 

F.  Never place a connected keg on the bottom row. The door will not close properly. This might

 

 

 

result in damage to the cabinet door, keg connector and/or the connected keg.

 

 

G.  A keg should only be replaced when completely empty. If beer is still present after 30 days,

 

 

 

empty the keg, then disconnect and replace it.

 

 

H.  Make sure the dispenser is well cleaned before loading a new keg.

 

 

I.  Do not reconnect a keg that has been used before. Once a keg is connected, use the keg until

 

 

 

empty. If the keg is disconnected and reconnected later, the beer quality is not

    guaranteed 

anymore.

3.   BEER DISPENSE
 

3.1   POURING RITUAL - STELLA ARTOIS

 

 

A.  THE PURIFICATION

 

 

 

The trademark Stella Artois chalice is designed to release the beer’s flavor and aroma.

 

 

 

Your bartender will always use one, preferably cleaned with a non-fat-based detergent.

 

 

 

It’s then rinsed with cold water, allowing the glass to reach the same temperature as the beer.

 

 

B.  THE SACRIFICE

 

 

 

Your bartender opens the tap in one swift motion to let the first burst of foam flow away.

 

 

 

It must never enter the chalice glass, thus ensuring that every drop of Stella Artois is fresh.

 

 

C.  THE LIQUID ALCHEMY BEGINS

 

 

 

The chalice glass is held at a 45-degree angle. When the beer hits the chalice and begins to

 

 

 

circulate, it creates the ideal proportion of foam relative to liquid.

 

 

D.  THE HEAD, ALTHOUGH “CROWN” WOULD BE MORE APPROPRIATE

 

 

 

The natural creation of the foam head occurs by straightening and lowering the glass.

 

 

 

This initial foam is important as it prevents the beer from coming into contact with the air and  

 

losing any flavor.

 

 

E.  THE REMOVAL

 

 

 

Your bartender then closes the tap in one quick action and moves the glass away from the font,

 

 

 

to prevent any drops from falling into the glass. These drops come into contact with the air, and

 

 

 

oxidize, making them unworthy of your glass of Stella Artois.

 

 

F.  THE BEHEADING

 

 

 

While the head is flowing over the edge of the glass, your bartender cuts it gently with a knife

 

 

 

on a 45-degree angle. This eliminates the larger bubbles, which burst easily and accelerate

 

 

 

the dissipation of the head.

 

 

G.  THE JUDGEMENT

 

 

 

The right amount of foam is about two fingers (3cm) thick. The final head creates a protective  

 

“cap” that keeps your Stella Artois from going stale.

 

 

H.  THE CLEANSING

 

 

 

Your bartender then rinses the bottom and sides of the glass. This step keeps the outside of the  

 

chalice clean and comfortable to hold.

 

 

I.  THE BESTOWAL

 

 

 

Finally, your Stella Artois is served to you on a coaster, accompanied by the drip catcher at the  

 

base. Behold the perfect glass of Stella Artois. Cheers to you, and for your patience, a 

    refreshing 

reward.

Summary of Contents for UTC

Page 1: ...729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com JUNE 2013 FOR QUALIFIED INSTALLER ONLY UNDER THE COUNTER BEER DISPENSER Operation Manual Lancer is the registere...

Page 2: ...8 1 1 UNPACKING 8 9 1 2 SELECTING A LOCATION 9 1 3 ASSEMBLING THE UNIT 9 1 4 CONNECTING TO ELECTRICAL POWER 10 1 5 CONNECTING THE DRAIN 10 1 6 EQUIPMENT SETUP 10 2 GETTING STARTED 10 2 1 SETTING AND A...

Page 3: ...FROST CYCLE SEEMS TO BE TOO LONG FOR THE 115V MACHINE 22 6 13 CONDENSER FAN DOES NOT SHUT OFF 22 6 14 PRESSURE REGULATOR IS MALFUNCTIONING 22 6 15 UNIT IS IN STANDBY MODE 22 7 PROGRAMMING THE COOLING...

Page 4: ...IONS Width 23 6 inches 599 4 mm Depth 25 7 inches 652 8 mm Height 57 13 inches 1451 5 mm Tower Height 17 25 inches 438 2 mm SPACE REQUIRED Left Side 1 inch 25 4 mm Right side 1 inch 25 4 mm Back 1 inc...

Page 5: ...2 Tap handles 2 Casters 2 with brakes 2 without brakes 5 PRE INSTALLATION CHECKLIST BEFORE GETTING STARTED Each unit is tested under operating conditions and is thoroughly inspected before shipment At...

Page 6: ...ma para el dispensador es de 40 F a 86 F 4 4 C a 30 C No coloque la unidad de lado incluso durante el transporte No deje la puerta del armario abierta m s tiempo del necesario mientras el dispensador...

Page 7: ...saci n correcta de la cerveza No manipule el control del regulador de presi n No utilice ninguna otra fuente de presi n externa No conecte el barril proporcionado a cualquier otra fuente de presi n ex...

Page 8: ...tiene un enchufe puesto a tierra de 3 clavijas Si no se dispone de un toma el ctrico conectado a tierra de tres agujeros use un m todo aprobado para poner a tierra la unidad Al hacer las conexiones r...

Page 9: ...due to non use for a long period e G A holiday always remove the connected keg from the dispenser and dispose of it Once a keg has been connected the beer stays fresh for 30 days Siempre lea y siga l...

Page 10: ...cording to the surgeon general women should not drink alcoholic beverages during pregnancy because of the risk of birth defects Consumption of alcoholic beverages impairs your ability to drive a car o...

Page 11: ...properly grounded electrical outlet and to a drain or bucket that meets the requirements on pages 4 and 5 C The selected location must allow the unit to be leveled on all sides D The dispenser may be...

Page 12: ...ENCHUFE A UN TOMACORRIENTE A MENOS QUE EL VOLTAJE DE LA PLACA DE N MERO DE SERIE QUE SE MUESTRA ACEPTE LA CORRIENTE LOCAL MANTENGA EL DISPENSADOR CONECTADO EN TODO MOMENTO A MENOS QUE LAS INSTRUCCION...

Page 13: ...MENT IL EST RECOMMAND DE R GLER LA PRESSION L INT RIEUR DE LA PLAGE ADMISSIBLE POUR OBTENIR UNE DISTRIBUTION DE BI RE AD QUATE NE PAS JOUER AVEC LE CONTR LE DE R GULATION DE PRESSION A The pressure re...

Page 14: ...ONES DE VENTILACI N Y LAS ESQUINAS AVERTISSEMENT UNE MANIPULATION PRUDENTE EST REQUISE LORS DU D PLACEMENT DE L UNIT DE L ENTRETIEN ET L UTILISATION MANIPULEZ TOUJOURS L UNIT AVEC SOIN POUR VITER TOUT...

Page 15: ...some beer leakage and spillage in and around the dispenser A Place the keg vertically in front of the unit B Close the air valve C Open the release valve air will be released D Release for at least 30...

Page 16: ...he beer B THE SACRIFICE Your bartender opens the tap in one swift motion to let the first burst of foam flow away It must never enter the chalice glass thus ensuring that every drop of Stella Artois i...

Page 17: ...and 3 sanitary gloves WARNING IF A POWDER SANITIZER IS USED DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO ADDING TO THE SYRUP SYSTEM ENSURE SANITIZING SOLUTION IS REMOVED FROM THE DISPENSER AS INSTR...

Page 18: ...minimum of five gallons of sanitizing solu tion should be prepared Any sanitizing solution may be used as long as it is prepared in accor dance with the manufacturer s written recommendations and saf...

Page 19: ...SHOOTING GUIDE FOR END USER G J H K I 17 TROUBLE CAUSE REMEDY 5 1 Too much foam when beer dispensed A Beer is not cold enough B Tap not fully open C Pouring ritual not executed correctly D Glass not c...

Page 20: ...must be loaded on the top shelf of the refrigerator Make sure the kegs are inserted properly and pushed completely to the back Refer to Section 2 2 Connecting the Kegs B The keg connector must be fir...

Page 21: ...nnector Check if the valve on the beer tubing is in the open position Make sure that the beer tubing is untangled and check for any obstruction If issue still persists please replace the keg C Check t...

Page 22: ...nance and Cleaning to manually relieve the accumulated water from the tank If still not enough air flow then replace air compressor or inspect the air regulator B Replace air regulator 6 3 Air compres...

Page 23: ...ace main relay 6 7 Excessive ice build up around evaporator area A 115V machine has a defrost function which may need adjustment B 230V machine does not have a defrost function A Defrost can be modifi...

Page 24: ...re rated to withstand high pressure however this will result in a highly accelerated beer dispense from tap when opened A Close the beer valve and check the correct setting of the pressure regulator I...

Page 25: ...on until PA1 displays on the screen B When PA1 displays press the SET button once 0 will now display C When 0 displays press the UP button once setting the value to 1 When 1 displays press the SET but...

Page 26: ...ADJUSTING THE REFRIGERATION COMPRESSOR RELAY TRIPPING DIFFERENTIAL A Press the SET button until CP displays on the screen B When CP displays press SET once diF will display 1 diF is the refrigeration...

Page 27: ...10 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 10 1 WIRING DIAGRAM 25...

Page 28: ...10 2 EXPLODED VIEW 26...

Page 29: ...6 13 0008 Bushing Relief Heyco 1200 37 15 0223 Grommet Flex Slot 085W X 155D 38 18 0332 Reg Assy Liv 39 23 1554 Rack Liv 40 23 1611 Dryer Cap Tube Assy 031X72 Item Part No Description 41 30 11146 Cond...

Page 30: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: