5.3.5.5.2 Channel type - Status
For status sensors, the type of signal can be selected in the measurement range selection box. Available
for selection:
•
Status active = high
•
Status active = low
The scaling mode "Standard" can be selected for the status.
Measuring
ranges
Scaling mode
Comment
Status active =
high
Standard
It applies:
Signal minimum=0, signal maximum=1,
Minimum value at logical-0 is usually
the minimum value. 0 and maximum
value can be scaled.
It applies:
logic 1 (true) at high level, e. g. 5V or switch
open
logic 0 (wrong) at low level, e. g. 0V or switch
closed
Status active =
low
Standard
It applies:
Signal minimum=0, signal maximum=1,
Minimum value at logical-0 is usually
the minimum value. 0 and maximum
value can be scaled.
It applies:
logic 1 (true) at low level, e. g. 0V or switch
closed
logic 0 (wrong) at high level, e. g. 5V or switch
open
Select the scaling mode "Standard" for
"Status active=high"
and
"Status active=low".
However, in
this case the scaling is usually limited to the scaling of the value maximum (with signal minimum=0,
signal maximum=1, value minimum=0 (usually)).
Examples of status sensors
Status 0…100%
The upper figure shows an example of the scaling for a sensor with status output whose measured
value is raised to the values 0 or 100. This means that an average value can be displayed for the sta-
tus in %. A value of 50% then means that the status was 50% of the measurement interval active and
50% inactive.
Summary of Contents for Ser[LOG]
Page 9: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 9 of 129 21 Technical data 127 22 Disposal 129...
Page 68: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 68 of 129 This choice leads to the following graph...
Page 92: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 92 of 129 12 Managing the safety settings...
Page 101: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 101 of 129...
Page 102: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 102 of 129...
Page 103: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 103 of 129...
Page 104: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 104 of 129...
Page 105: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 105 of 129...
Page 106: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 106 of 129...
Page 107: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 107 of 129...