5.3.5.4
Configuration of sensors with look-up table
A look-up table can be stored for sensors with a special signal characteristic curve. See also section
5.3.6.5 "Creating new sensors".
In the look-up table, markers of the signal
characteristic curve can be entered be-
tween which linear interpolation is per-
formed. The order in which the sampling
points are entered is arbitrary. If the win-
dow is closed via the "OK" button (green
token), the table is automatically sorted
and saved.
Note:
If you want to delete a marker,
simply double-click on the number field
(1-15) of the respective line.
Example:
0
10
20
30
40
50
60
70
80
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
0
10
20
30
40
50
60
70
80
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
markers
Signal characteristic curve
Look-up table curve
1
2
3
4
5
6
7
8
9
10
0.0000
1.0000
2.0000
3.0000
4.0000
6.0000
7.0000
8.0000
9.0000
10.0000
12.0000
11.0000
13.0000
14.0000
0.0000
14.0000
22.0000
25.0000
27.0000
28.0000
80.0000
29.0000
32.0000
37.0000
54.0000
44.0000
65.0000
71.0000
75.0000
Signal:
Value:
5.0000
Look-up-table
11
12
13
14
15
5.3.5.5
Creating new sensors
If you use sensors that are not included in the predefined sensors, you can create your own new sen-
sors. New sensors can be defined for:
Serial
•
SDI-12
•
Modbus RTU
•
Modbus TCP
•
NMEA
A list of supported NMEA da-
tasets can be found in chapter
Digital and status
•
Status
•
Impulse
•
Frequency
As switch (relay, reed), open
collector (OC) or logic signal
(0/1) from 0...30V
Analogue signals
•
5 V bipolar,
•
5 V unipolar,
•
50 mV bipolar,
•
0/4…20 mA,
•
500 Ohm and
•
5000 Ohm.
To create new sensors, first close the configuration window.
Click on the "Define sensors" button in the main selection to open the "Define sensors" window.
Important note:
Be careful when configuring new sensors. Due to the approach of ensuring
the greatest possible flexibility in configuration, it is also possible to create "nonsensical" sensor config-
urations that could interfere with the operation of the Ser[LOG]. It is therefore recommended to work
with the predefined sensors if possible or to derive new sensors from existing sensors!
Summary of Contents for Ser[LOG]
Page 9: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 9 of 129 21 Technical data 127 22 Disposal 129...
Page 68: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 68 of 129 This choice leads to the following graph...
Page 92: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 92 of 129 12 Managing the safety settings...
Page 101: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 101 of 129...
Page 102: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 102 of 129...
Page 103: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 103 of 129...
Page 104: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 104 of 129...
Page 105: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 105 of 129...
Page 106: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 106 of 129...
Page 107: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 107 of 129...