iXinox 24 C
37
EN
cod. 3541N452EN - Rev. 03 - 03/2020
Disassembling the burner and cleaning the exchanger
fig. 42
•Disconnect the power supply and turn off the gas cock ahead of the valve.
•Undo the 5 screws securing the exchanger cover.
•Undo the 3 screws securing the burner.
•Check the correct distance of the electrodes.
•To clean the exchanger, it is advisable to remove the electrode (see fig. 45)
•Clean the inside of the exchanger with the accessories indicated in fig. 42.
Do not use metal brushes which could damage the exchanger.
3.5 mm
2
1