iXinox 24 C
30
EN
cod. 3541N452EN - Rev. 03 - 03/2020
Procedure for modifying parameter SC12:
•Put the boiler in heating or DHW mode and press the
reset
button (ref. 6 fig. 1) for 10 seconds.
•The display shows 100 and the text
”Co”
flashing; press the "H" button (ref. 4 fig. 1) to set and view 120.
•Then press the "DHW +" button (ref. 2 fig. 1) to set 123.
•Press the
reset
button (ref. 6 fig. 1) once.
•The display shows
Ts
flashing; press the "h" button (ref. 4 fig. 1) once.
•The display shows
Sc
flashing; press the
reset
button once.
•The display shows
Sc
alternating with 01 flashing;
•Press the "h" button (ref. 4 fig. 1) until displaying
Sc
alternately with 15 flashing;
•Press the "DHW +" button and the display shows "00";
•Press the "DHW +" button until the display shows "02";
•Press the "h" button (ref. 4 fig. 1) to confirm and the 100% calibration mode will activate displaying the message
“CA” and “LI” alternating.
•after just over a minute the calibration mode will end and the display will show "C" alternating with "12" with the conti-
nuous flame symbol.
•press the "DHW +" or "DHW -" button to set the "SC12" parameter value to the value that allows CO
2
optimization.
•press the "h" button to confirm the value. The display shows "Sc" alternating with "15".
•Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to exit the card Service
Menu, or exiting occurs automatically after 15 minutes
•put the boiler in TEST mode and check the CO
2
value at maximum and minimum power with an analysis instrument.
Procedure for modifying parameters SC12 and SC13:
•Put the boiler in heating or DHW mode and press the
Reset
button (ref. 6 fig. 1) for 10 seconds.
•The display shows 100 and the text
”Co”
flashing; press the "H" button (ref. 4 fig. 1) to set and view 120.
•Then press the "DHW +" button (ref. 2 fig. 1) to set 123.
•Press the
Reset
button (ref. 6 fig. 1) once.
•The display shows
Ts
flashing; press the "h" button (ref. 4 fig. 1) once.
•The display shows
Sc
flashing; press the
reset
button once.
•The display shows
Sc
alternating with 01 flashing;
•Press the "h" button (ref. 4 fig. 1) until displaying
Sc
alternately with 15 flashing;
•Press the "DHW +" button and the display shows "00";
•Press the "DHW +" button until the display shows "03";
•Press the "h" button (ref. 4 fig. 1) to confirm and the 100% calibration mode will activate displaying the message
“CA” and “LI” alternating.
•after just over a minute the calibration mode will end and the display will show "C" alternating with "12" with the conti-
nuous flame symbol.
•press the "DHW +" or "DHW -" button to set the "SC12" parameter value to the value that allows CO
2
optimisation.
•press the "h" button to confirm the value. The display shows "CA" and "LI" alternately to indicate that a further
calibration is being performed.
•after just over a minute the calibration mode will end and the display will show "C" alternating with "15" with the conti-
nuous flame symbol.
•press the "DHW +" or "DHW -" button to set the "SC13" parameter value to the value that allows CO
2
optimization.
•press the "h" button to confirm the value. The display "SC" appears alternately to "15".
•Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to exit the card Service
Menu, or exiting occurs automatically after 15 minutes
•put the boiler in TEST mode and check the CO
2
value at maximum and minimum power with an analysis instrument.