iXinox 24 C
26
EN
cod. 3541N452EN - Rev. 03 - 03/2020
b25
CPVC flue shutdown maximum
temperature
60-110°C
98°C
b26
Flow temperature limit in automa-
tic calibration
25°C ÷ 55°C
30°C
b27
Maximum temperature during
calibration in DHW mode
75°C ÷ 95°C
80°C
b28
Flowmeter sensitivity factor
0 ÷ 60 (0 = disabled)
20
b29
Restoring Factory Values
Change the value from 0 to 10 by pressing the
“DHW +”
but-
ton. Confirm by pressing the
“h”
button.
-
P30
Heating ramp
1-20°C/minute
4°C/minute
P31
Virtual setpoint min. temperature
(b01=1)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature
(b01=2)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature
(b01=3)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature
(b01=4)
0=Deactivated, 1-80°C
0=Deactivated
P32
Heating standby time
0-10 minutes
4 minutes
P33
Heating Post-Circulation
0-255 minutes
15 minutes
P34
Pump operation
0-3 = Operation strategy
2
P35
Modulating pump min. speed
30-100%
30%
P36
Modulating pump start speed
90-100%
90%
P37
Modulating pump max. speed
90-100%
100%
P38
Pump deactivation temperature
during Post-Circulation (b01=1)
0-100°C
50°C
Pump deactivation temperature
during Post-Circulation (b01=2)
0-100°C
55°C
Pump deactivation temperature
during Post-Circulation (b01=3)
0-100°C
55°C
Pump deactivation temperature
during Post-Circulation (b01=4)
0-100°C
55°C
P39
Pump activation hysteresis tem-
perature during Post-Circulation
(b01=1)
0-100°C
10°C
Pump activation hysteresis tem-
perature during Post-Circulation
(b01=2)
0-100°C
25°C
Pump activation hysteresis tem-
perature during Post-Circulation
(b01=3)
0-100°C
25°C
Pump activation hysteresis tem-
perature during Post-Circulation
(b01=4)
0-100°C
25°C
P40
Heating user max. setpoint
20-90°C
80°C
P41
Max. output in heating
0-100%
80%
P42
Burner shutdown in DHW
(b01=1)
0=Fixed, 1=Linked to setpoint, 2=Solar
0=Fixed
Legionella protection (b01=2)
0-7=Days of activation (1 = Once every 24 hours / 7= Once
every 168 hours)
0=No protection
Burner shutdown in DHW
(b01=3)
0=Fixed, 1=Linked to setpoint, 2=Solar
0=Fixed
Legionella protection (b01=4)
0-7=Activation days
0=No protection
P43
Comfort activation temperature
(b01=1)
0-50°C
40°C
Storage tank hysteresis (b01=2)
0-60°C
2°C
Comfort activation temperature
(b01=3)
0-80°C
40°C
Storage tank hysteresis (b01=4)
0-60°C
2°C
Contents
Description
Range
Default