Safety
17
4.
IF ANY hydraulic function is OPERATIONAL when the ladder is deployed, NOTIFY your
maintenance supervisor immediately.
Location: This proximity switch is located at the base of the access ladder.
Figure 2-14 Access ladder proximity switch
Figure 2-15 IQAN MDM display screen
Arm Limit Switches (2)
Performing this test ensures the
Arm not parked
message
will appear on the IQAN MDM screen
(see Figure 2-15) when the slide is extended from the home position.
Failure to heed this warning
message may result in serious personal injury or material damage from a lift which is extended
during travel.
This warning also prevents dumping of refuse outside the hopper.
To perform this test:
1.
PARK the vehicle in a non-traffic area.