Maintenance
93
Adjusting Packer Counter Balance Valve
To adjust the packer counter balance valve, do the following:
1.
ACTIVATE the packer retract let-off switch.
2.
SCREW IN the counter balance valve until the packer drifts down.
3.
BACK OUT the valve until the packer maintains full up position.
Figure 3-68 Packer counter balance valve
Adjusting Packer Choke Valve
To adjust the packer choke valve:
1.
LOCATE the choke valve on the front side of the packer valve (see Figure 3-69).
2.
REMOVE cap from the valve.
3.
With the auto-pack running, SCREW the adjustment screw in until there is approximately
½
second delay between each cylinder stroke shift.
N
OTE
:
If the pendulum packer hits hard at the end of its upper or lower stroke, you can adjust the
cushioning speed by which the packer ends its stroke by using this choke valve (see Figure
3-69). Turn the valve clockwise or counter-clockwise to reach the proper adjustment. Several
attempts and testing may be required.