OFF*
Electric lock not active when the door is closed in the EXIT ONLY work program
ON
Electric lock active when the door is closed in the EXIT ONLY work program
OFF
Battery pack not installed
ON
Battery pack installed
OFF*
Operation when powered by battery: if the mains power supply is off the door keeps working normally
ON
Operation when powered by battery: if the mains power supply is off the door opens and stays open in the automatic work programs
OFF*
Battery monitoring: if the battery is low or damaged the control unit buzzer beeps before the door opens for ten cycles
ON
Battery monitoring: if the battery is low or damaged the door opens and stays open in automatic programs.
OFF*
Operation without mains power supply with battery getting depleted: the door works normally
ON
Operation without mains power supply with battery getting depleted: the door opens and stays open
OFF*
In absence of main power supply in the night lock program the control unit remains powered by the battery until it is exhausted.
ON
OFF
Automation model: ETERNA 150 / 300T (telescopic door)
ON
Automation model: ETERNA 90
OFF
E.C.1 closing safety sensor input inactive; when the safety sensor is not installed on the E.C.1 input
ON
E.C.1 closing safety sensor input active; closing safety sensor on E.C.1 input installed
OFF
E.C.2 closing safety sensor input inactive; when the safety sensor is not installed on the E.C.2 input
ON
E.C.2 closing safety sensor input active; closing safety sensor on E.C.2 input installed
OFF
E.O.1 opening safety sensor input inactive; when the safety sensor is not installed on the E.O.1 input
ON
E.O.1 opening safety sensor input active; opening safety sensor on E.O.1 input installed
OFF
E.O.2 opening safety sensor input inactive; when the opening safety sensor is not installed on the E.O.2 input
ON
E.O.2 opening safety sensor input active; opening safety sensor on E.O.2 input installed
OFF
Test on closing safety sensors E.C.1 and E.C.2 inactive; for sensors which are not pre-arranged for the monitoring
ON
OFF
Tests on opening safety sensors E.O.1 and E.O.2 inactive; for sensors which are not pre-arranged for the monitoring
ON
OFF
Safety sensor test with logic level LOW. For further information please refer to the "Safety sensors" paragraph.
ON
Safety sensor test with logic level HIGH. For further information please refer to the "Safety sensors" paragraph.
OFF*
The activation of the safety sensor in opening E.O.1 / E.O.2 has effect for entire opening stroke.
ON
The activation of the safety sensor in opening E.O.1 / E.O.2 has effect in the last 500mm of the opening stroke.
OFF*
The activation of the safety sensor during opening slows down the leaf opening motion until the end of the stroke is reached.
ON
The activation of the safety sensor during opening stops the leaf motion until the obstacle is removed.
F03
1
F02
F07
F08
F09
F19
F01
F10
F16
1
Function active if
F12 o F13= ON
F15
1
F14
1
F13
1
F12
1
F11
1
F06
1
F05
F04
1
F20
F18
1
Function active if
F16 o F17= ON
F17
1
Function active if
F14 o F15= ON
40
FUNCTION
EXPLANATION
FUNCTION TABLE
STATUS
Function to be set in the "Initial set-up" menu of the digital programmer before starting the door
* Default setting of the function
OFF*
PRJ38 FT1/FR3 photocell: not installed.
ON
PRJ38 FT1/FR3 photocell: installed.
OFF*
Photocell PRJ38 FT1/FR1 working as a stop sensor in the panic exit breakout system.
ON
F21
F22
Function active if
F21=ON
OFF*
Choice of the work program selector: ET-DSEL or T-NFC digital programmer
ON
Choice of the work program selector: EV-MSEL mechanical selector
OFF*
Standard function: the electric lock activates when the door is closed only in the Night Lock work program.
ON
Bank function: the electric lock activates when the door is closed in all work programs
OFF
Electric lock type selection: FAIL SECURE «EV-EBSFSE» or BISTABLE «EV-EBSBIS»
ON
Electric lock type selection: FAIL SAFE «EV-EBSFSA»
OFF
Electric lock for chemist's function not installed
ON
Double electric lock for chemist's function: active.
Please refer to the "Special functions with double electric lock → Chemist's function" paragraph.
In absence of main power supply in the night lock program and door closed, the automation switches to stand-by status to minimize battery consumption.
To restart the automation from stand by status give a pulse command on the Wake input (terminals 28-29).
Please refer to the "STAND BY SWITCHING" paragraph.
The function is active if F12 or F13=ON. Test on closing safety sensors E.C.1 and E.C.2 active; for sensors pre-arranged for automatic door monitoring
by the operator (cat.2/pl.c). For further information please refer to the "Safety sensors" paragraph.
The function is active if F13 or F14=ON. Test on opening safety sensors E.O.1 and E.O.2 active; for sensors pre-arranged for automatic door
monitoring by the operator (cat.2/pl.c). For further information please refer to the "Safety sensors" paragraph.
Photocell PRJ38 FT1/FR1 working as safety photocell in closing.
Attention!
This function doesn't guarantee safety during closing as required by the EN16005 standard. The use of the PRJ38 photocell is only
acceptable in addition to the safety sensors monitored.