OFF
OPEN input configuration: normally closed contact. When a device with N.C. contact is installed.
ON
OPEN input configuration: normally open contact. When not in use or if a device with N.O. contact is installed
F23
1
FUNCTION
EXPLANATION
STATUS
OFF
STOP/INTERLOCK input configuration: normally closed contact N.C.
ON
STOP/INTERLOCK input configuration: normally open contact N.O.
OFF
In case of failure of the closing safety sensor test the door stays open
ON*
In case of failure of the closing safety sensor test the door closes slowly after 30 seconds
OFF*
Constant pause time before automatic reclosing
ON
Automatic increase of the pause time if the door cannot close due to the high flow of people.
OFF*
Interlock function inactive.
ON
Interlock function between two doors active. The opening of a door is possible if the other door is closed.
Please refer to the "Interlock system" paragraph.
OFF*
Door opening is delayed by 0,5" after the issuing of the relevant command. Please refer to the "Interlock system" paragraph.
ON
The door opens immediately after the issuing of the relevant command. Please refer to the "Interlock system" paragraph.
OFF*
The opening command is not stored in memory. Please refer to the "Interlock system" paragraph.
ON
The opening command is stored in memory. Please refer to the "Interlock system" paragraph.
OFF*
Operation with automatic closing
ON
OFF*
Hold to run control inactive.
ON
Hold to run control active. The START input controls the opening of the door with maintained action,when the command is released the door stops.
OFF*
ON
OFF*
Switching from reduced opening during winter to full opening inactive.
ON
Switching from reduced opening during winter to full opening active. If the door cannot close due to the high flow of people,
after approximately one minute it switches from reduced opening to full opening.
OFF*
Dynamic winter opening inactive.
ON
Dynamic winter opening active.
During the winter opening programme a full door opening is achieved if both internal and external radars are engaged at the same time.
OFF*
Energy saving function inactive.
ON
Energy saving function active. The door closes back as soon as the opening radars and the closing safety sensors are no longer engaged,
to minimise the amount of time during which the door stays open. To maximise the benefit of this function, we recommend that you
install uni-directional activation sensors.
Multiple selection function that allows to set the "Free manual door" program in the EV-MSEL mechanical key selector, replacing the
standard program in the selected position.
A*
Standard operation of the EV-MSEL mechanical key selector (free manual door program not enabled)
B
Free manual door program enable in "exit only" position.
C
Free manual door program enable in "night lock" position.
D
Free manual door program enable in "partial opening winter" position.
F36m
Multiple
selection
function
F31
F32
F33
F34
F35
F29
Function active if
F27= ON
F30
F24
1
F25
F26
F27
F28
Function active if
F27= ON
OFF*
START input: it is enabled to open the door when any work program is selected
ON
START input: it is only enabled when the automatic programs are selected. It doesn't open the door when the Night Lock program is selected.
Note 1:
don't select ON if the Label radio transmitter with an EN/RF1 radio receiver are installed to open the door in the night lock program.
Note 2:
don't select ON if the function stand-by switching → F10=ON is enable.
OFF
The F1 button of the ET-DSEL digital programmer or the B button of the T-NFC programmer controls door opening in automatic programs only.
ON*
The F1 button of the ET-DSEL digital programmer or the B button of the T-NFC programmer controls door opening both in automatic
programs and in night lock mode.
OFF*
It enables the warning beep by the buzzer when the motor thrust power limit is reached. Please refer to the "Functional testing" paragraph.
ON
It disables the warning beep by the buzzer when the motor thrust power limit is reached.
F38
F39
F40
Multiple selection function that allows to set the operating mode of the OUT1 output for the UR24E relay module.
ATTENTION! If the interlock function is selected → F27 = ON the output OUT1 works as an interlock signal and all the set functions by
F41m are automatically excluded.
A
The output shows the status of the LOCK1 input of the ET-LOGIC-B control unit. Output active with contact closed, deactivate with open contact.
This function can be used to indicate the status of the electric lock and the leaf position when installing the electric lock with microswitch.
Please refer to the "Electric lock → Electric connection" paragraph.
Door crossing warning GONG. The gong function is a entry warning triggered by the activation of the closing safety sensor
B
(that is the sensor connected to the E.C.1 terminal, or to the E.C.2 terminal) while the automatic door is being crossed.
Please refer to the "Gong function" paragraph.
C*
Air blade, device generating a flow of cold or heated air to separate the outside temperature from the inside one.
The output activates when the door opens and deactivates when the door closes.
D
Battery status. The activation of the output signals the damaged battery status.
E
Door status. Blinking slowly while the door is opening, on when the door is open, blinking fast when the door is closing,
off when the door is closed.
F
Alarm warning.
It activates for two seconds if the radar or the closing safety sensor are engaged while the door is closed in Night Lock mode.
F41m
Multiple
selection
function
Maintenance signal.
G
The output activates when the door reaches the number of cycles set in the maintenance plan by potentiometer P48.
H
Unused function
41
Step-by-step function on START or OPEN input. Here the function for each input:
START INPUT: the first command open the door, the second one stops the door during opening and the third one will close the door.
OPEN INPUT: the first command open fully the door, a second one will close the door.
The AUX2 input controls the closing of the door with maintained action, when the command is released the door stops.
The "step by step" mode works as described in function F30 = ON.
The step by step function works with the opening and closing commands on two separate inputs of the ET-LOGIC-B electronic control unit.
The START and OPEN inputs opening the door, the AUX2 input closing the door.