EN
37
Display
Operating Procedure
Description
Programming Mode
Accessing Programming Mode
• To change the values of any parameter
the operator must first enter into the
programming mode.
• There are two levels within the
programming mode that allow the
programming of specific parameters.
• The two programming levels are as
follows:
•
Barista Programming
- The parameters
contained within this level are ones
the operator can change to affect the
quality of the espresso.
No password is required for access.
Programming Mode
94.4 00:00
95.5 95.1 SB
94.4 00:00
95.5 95.1 SB
1
Barista” Programming Level
While the espresso machine is on, press and hold the button T3
. After approximately 5 seconds the
following display appears.
Program
Dose
Press Enter
To Exit
2
This is the “Barista” programming level. To program the brewing amount for each button, to set the coffee
boilers, the pre-infusion, and to enable/disable the resistance of the cup warmer if present.
To exit the programming mode, scroll to the exit menu, using the buttons T1
or T2
. Press the T3
button to confirm the exit, or press at the same time the buttons T2 and T3.
Exit
Menu
3
To exit the programming mode, scroll to the exit menu, using the buttons
T1
or T2
. Press the
T3
button to confirm the exit, or press at the same time the buttons T2 and T3.
Summary of Contents for kb90 Series