Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Enter Password
******
Coffee Boiler
Settings
CB1 Offset
3.0°C
5
Press the T3 button
to enter the menu, move with the buttons T1
and T2
to set the desired
temperature, press the T3 button
to confirm the value. In the case of espresso machine with 4 groups
you can set this value also on the coffee boiler 2.
CB1 RTD Trim
0
6
Press the T3 button
to enter the menu, move between the parameters with the buttons T1
and T2
to set the desired value, press the T3 button
to confirm the value.
CB Settings
Exit
7
Press the T3 button
to return to the “Technical” programming.
8
Press T1
or T2
to continue with the programming of the other parameters.
Coffee Boiler
• The OFFSET parameter is used to
calibrate the coffee boiler temperature
system to ensure the display temperature
accurately represents the temperature
of the water exiting the group head.
• This parameter is preset at the factory
based upon initial tests of this espresso
machine.
• It is not recommended that this number
is changed. Changes to this parameter
can cause unexpected results.
• It is important to write down this value
before making changes to be sure you
can return to the factory programming if
unexpected results occur. Each machine
may have a different value as it is set
individually.