Display
Operating Procedure
Description
Programming Mode
“Technical” Programming
Enter Password
******
Flush
ENABLED
Flush
Enter Password
******
1
After accessing the “Technical” programming menu and entering the password, use the buttons
T1
and T2
until the following screen is displayed.
Flush
DISABLED
2
Press the T3 button
to enter the menu, move between the parameters using the buttons T1
and T2
to select
ENABLED
or
DISABLED
, press the T3 button
to confirm the option.
3
Press T1
or T2
to continue with the programming of the other parameters.
• This parameter allows the technician to
enable or disable the Flush function.
• If the Flush function is enabled in the
menu, hot water will be delivered by the
group with a delay of 2 seconds form
portafilter removal.
THE COFFEE BOILER CONTAINS WATER AT ELEVATED TEMPERATURES.
WATER TEMPERATURE OVER 52°C CAN CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING.
WARNING