SERVICE BULLETIN
FA2100CVDR
BULLETIN NO. FA2100CVDR SB017 R1
AVIATION RECORDERS
100 Cattlemen Rd., Sarasota, FL 24232
Telephone: 941-371-0811 Facsimile: 941-377-5591
Page 9 of 11
23‐70‐07-017 R1
(14) Observe the progress window and verify that a status pop
−
up window ap-
pears stating that the FA2100 loaded successfully.
Note:
If the load procedure was unsuccessful, remove the CD from the D:\
drive, exit the CICC loader program, turn OFF power to the FA2100
CVDR Recorder, and repeat steps (5)
−
(15).
D:\
Figure 2. CICC Loader Window
(15) Remove power from the recorder and Exit the CICC Loader utility pro-
gram.
(16) Disconnect the Software Upload Cable 17TES0058 from the FA2100 front
panel GSE connector and CICC Cable Assembly.
C.
To Verify the Software Upload
Once the FA2100 software has been loaded, it needs to be verified using the
CICC Interface utility program on the ROC/6 or ROC/7 Ground Station:
(1) Connect Computer Interface Communications Cable/2 (CICC/2) (P/N:
17TES0072 and 17TES0070) to FA2100CVDR front panel GSE connec-
tor.
(2) Apply power to the FA2100CVDR Recorder and to the ROC/6 or ROC/7.
The document reference is online, please check the correspondence between the online documentation and the printed version.