SERVICE BULLETIN
FA2100CVDR
BULLETIN NO. FA2100CVDR SB017 R1
AVIATION RECORDERS
100 Cattlemen Rd., Sarasota, FL 24232
Telephone: 941-371-0811 Facsimile: 941-377-5591
Page 10 of 11
23‐70‐07-017 R1
(3) At the Windows desktop, shut down the Recorder Interface (RI) if not
already shutdown from previous steps by right clicking on the RI Icon in
the Windows System Icon Tray at the bottom right of the screen. Select
“shutdown.”
(4) Also shut down the FTP program by right clicking on the FTP Icon in the
Windows System Tray at the bottom right of the screen. Select “Exit”.
(5) From the Windows desktop, activate the CICC Interface utility program by
double
−
clicking on the CICCIfc Icon.
(6) From the CICC Interface Menu, select the “Version” Command from the
list and left click the “Send” Command button. Observe that a pop-up
window appears showing the recorder software Part Number and SMP &
FDP Checksums.
(7) Match the listed SW Part Number and SMP & FDP Checksums with the
ones listed on the recorder software CD.
(8) Left click the OK button and left click the “Exit” button on the CICC Loader
Menu to exit the utility and return to the Windows desktop.
(9) Once the Software upload versions are validated, perform a full Return To
Service test procedure as listed in Sections 100 & 200 of the
FA2100CVDR CMM, ATA 23
−
70
−
07, P/N 165E1690
−
00.
D.
Modification Information
Incorporation of this Field Service Bulletin will be identified by marking in the
software revision section of the recorder’s name plate with black paint.
The document reference is online, please check the correspondence between the online documentation and the printed version.