1.6 FEET POSITIONING AND ADJUSTMENT
Place the oven perfectly upright, adjusting if necessary the screw feet of the legs of
the appliance to adjust the level.
Check evenness with a spirit level.
The oven must be placed on a perfectly flat surface in order to work properly and
to allow correct water drainage. Noisy motor vibrations also are avoided.
2. ELECTRICAL CONNECTION AND EARTHING
2.1 ELECTRICAL POWER SUPPLY
The installation and the electrical connections must be carried out in conformity with the electri-
cal rules in force. These operations must be carried out by qualified staff.
The Company declines any responsibilities originated from the no observance of the
above rules in force.
See the OVEN wiring diagram at the end of this manual.
BEFORE PLUGGING IN:
Before plugging in the oven
it is necessary to proceed with its complete and careful cleaning
using
warm water with no aggressive detergents and drying with a soft cloth all the humid parts.
In order to carry out a correct plug in you must proceed as follow:
•
Arrange a differential circuit breaker
and verify that the frequency / tension of the line correspond
to those written on the identification label of the Oven
•
Check the supply voltage at the socket,
is the n-10% at power up.
•
It is advisable to
fit a 4-pole disconnection switch
with a contact gap of at least 3 mm, upstream of the
socket This switch is mandatory when the load is greater than 1000 Watts or when it is connected directly
without the use of the plug and must be placed in the immediate vicinity of the oven in such a way that it
can be clearly visible by the technician in case of maintenance
•
It is necessary that
the connection cable section is commensurate to the
power consumption of
the unit.
•
The law requires that
the unit is earthed;
therefore it is necessary to connect it to an efficient earth
connection.
The plug of the oven must always be connected to a fixed socket
.
It is forbidden to connect the plug of the oven to an extension cord and/or or to a reducer.
ATTENTION
If the supply cable is damaged, it must be replaced by the manufacturer or by the latter’s technical as-
sistance service or anyhow by a person with similar qualification, such as to prevent any risk
6
Summary of Contents for VULCAIN-2/3
Page 25: ...49 NOTES 24...