![background image](http://html1.mh-extra.com/html/l-b-white/guardian-series/guardian-series_owners-manual-and-instructions_3184424019.webp)
Guardian with Smart Sense™
Owner’s Manual • Guardian
19
Service Instructions
1. Close the fuel supply valve to the heater
and disconnect the electrical supply before
servicing unless necessary for your service
procedure.
2. Clean the heater’s ori
fi
ce with compressed
air or a soft, dry rag. Do not use
fi
les, drills,
broaches, etc. to clean the ori
fi
ce hole.
Doing so will enlarge the hole, causing
combustion or ignition problems. Replace
the ori
fi
ce if it cannot be cleaned properly.
3. The high limit switch can be tested by:
-- Disconnecting the leads at the compo-
nent, and jumpering the leads together.:
-- Reconnect the electrical supply and open
fuel supply valves.
-- If the heater lights, the component is
defective and must be replaced.
-- Do not leave the jumper on or operate the
heater if the part is defective. Replace the
part immediately.
-- An alternate method for checking the
components is to perform a continuity
check.
WARNING
Burn Hazard
■
Heater surfaces are hot for a period of time after
the heater has been shut down.
■
Allow the heater to cool before performing
service, maintenance, or cleaning.
■
Failure to follow this warning will result in burns
causing injury.
WARNING
Fire and Explosion Hazard
■
Do not disassemble or attempt to repair any
heater components or gas train components
such as gas valves, or gas hoses.
■
All component parts must be replaced if defects
are found.
■
Failure to follow this warning will result in
fi
re or
explosions, causing property damage, injury, or
death.
Motor & Fan Assembly
1. Open louvered access panel opposite burner
end of heater. Disconnect motor leads.
2. Remove all screws securing motor mounting
plate to housing.
3. Pull fan and motor assembly from housing.
4. Loosen set screws on fan wheel.
5. Pull fan wheel from motor shaft.
6. Remove the four nuts securing motor to mount-
ing plate
FIG. 10
SCREWS
MOTOR MOUNT PLATE
4. The air proving switch must not be jumpered. If
jumpered, the ignition control will not allow heater
operation. Test the air proving switch for continu-
ity. If defective, replace the switch.
5. Open the respective case panel for access to
burner or fan related components. Open the
control box for access to the ignition controller,
transformer, and signal conditioner.
6. Disconnect the appropriate electrical leads when
replacing components.
7. For reassembly, reverse the respective service
procedure. Ensure gas connections are tightened
securely.
8. After servicing, start the heater to ensure proper
operation and check for gas leaks.
Summary of Contents for Guardian Series
Page 46: ...Guardian with Smart Sense www lbwhite com Owner s Manual Guardian 46 Notes...
Page 47: ...Guardian with Smart Sense Owner s Manual Guardian 47 Notes...
Page 94: ...Guardian con Smart Sense www lbwhite com Manual del usuario Guardian 46 Notas...
Page 95: ...Guardian con Smart Sense Manual del usuario Guardian 47 Notas...
Page 142: ...Guardian avec Smart Sense www lbwhite com Manuel du propri taire Guardian 46 Remarque...
Page 143: ...Guardian avec Smart Sense Manuel du propri taire Guardian 47 Remarque...